The rapid advancement of diagnostic and therapeutic optical techniques for oncology demands a good understanding of the optical properties of biological tissues. This study explores the capabilities of hyperspectral (HS) cameras as a non-invasive and non-contact optical imaging system to distinguish and highlight spectral differences inbiological soft tissuesof three structures (kidney, heart, and liver) for use inendoscopic interventionoropen surgery. The study presents an optical system consisting of two individual setups, the transmission setup, and the reflection setup, both incorporating anHS camerawith apolychromatic light sourcewithin the range of 380 to 1050 nm to measure tissue's light transmission (T) and diffuse light reflectance (R), respectively. The optical system was calibrated with a customizedliquid optical phantom, then 30 samples from various organs were investigated fortissue characterizationby measuring both T and R at the visible and near infrared (VIS-NIR) band. We exploited the ANOVA test, subsequently by a Tukey's test on the created three independent clusters (kidney vs. heart: group I / kidney vs. liver: group II / heart vs. liver: group III) to identify the optimum wavelength for each tissue regarding their spectroscopic optical properties in the VIS-NIR spectrum. The optimum spectral span for the determined light T of the three groups was 640 ∼ 680 nm, and the ideal range was 720 ∼ 760 nm for the measured light R for mutual group I and group II. However, the group III range was different at a range of 520 ∼ 560 nm. Therefore, the investigation provides vital information concerning theoptimum spectral scalefor the computed light T and R of the investigatedbiological tissues(kidney, liver, and heart) to be employed in diagnostic andtherapeutic medical applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.saa.2023.123363 | DOI Listing |
J Fluoresc
January 2025
Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore -14, Tamil Nadu, India.
This study addresses the critical issue of irreversible oxidation in hypochlorite (ClO⁻) sensing by a phenothiazine-based compound, which typically leads to the probe's degradation and loss of functionality. We introduce a novel fluorescence probe, (2-(5-(10 H-phenothiazin-10-yl)thiophen-2-yl)-1 H-benzo[d]imidazol-6-yl)(phenyl)methanone (PTH-BP), specifically designed to enhance ClO⁻ detection efficiency. PTH-BP exhibits strong aggregation-induced emission (AIE), emitting deep orange fluorescence at 620 nm with a large Stokes shift of 195 nm, and achieves an impressive detection limit of 1 nM in ACN/PBS buffer solutions.
View Article and Find Full Text PDFEnviron Monit Assess
January 2025
Department of Landscape Architecture, Remote Sensing and GIS Laboratory, University of Cukurova, Adana, 01330, Turkey.
Recent advancements in satellite technology have greatly expanded data acquisition capabilities, making satellite imagery more accessible. Despite these strides, unlocking the full potential of satellite images necessitates efficient interpretation. Image classification, a widely adopted for extracting valuable information, has seen a surge in the application of deep learning methodologies due to their effectiveness.
View Article and Find Full Text PDFMol Biol Rep
January 2025
Department of Pathology and Laboratory Medicine, Baylor Scott and White Medical Center, Baylor College of Medicine, Temple, TX, USA.
Background: Brain intraparenchymal schwannoma is a rare clinical entity, generally curable with adequate resection.
Methods And Results: We describe a case in a male patient first presenting at 19 months of age, the youngest reported age for this lesion. It also appears to be the first case connected to a germline TSC2 p.
Vis Comput Ind Biomed Art
January 2025
School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
Fluorescence endoscopy technology utilizes a light source of a specific wavelength to excite the fluorescence signals of biological tissues. This capability is extremely valuable for the early detection and precise diagnosis of pathological changes. Identifying a suitable experimental approach and metric for objectively and quantitatively assessing the imaging quality of fluorescence endoscopy is imperative to enhance the image evaluation criteria of fluorescence imaging technology.
View Article and Find Full Text PDFEnviron Monit Assess
January 2025
Department of Chemistry, Vaal University of Technology, Vanderbijlpark, South Africa.
Due to incessant contamination of the groundwater system near the dumpsite in southwestern Nigeria Basement Complex, this study seeks to evaluate the impact of the Odogbo dumpsite on the local groundwater system by integrating geophysical and geochemical methodologies. Aeromagnetic data covering the study area was acquired, processed, and enhanced to delineate basement features that could potentially be passing plumes to the groundwater system. Concurrently, geoelectric methods using 2-D dipole-dipole imaging and vertical electrical sounding (VES) were utilized to characterize the vulnerability indices of the lithologies underlying the dumpsite.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!