A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-sensitivity fiber SPR strain sensor based on n-type structure. | LitMetric

AI Article Synopsis

  • Fiber strain sensors mostly use grating and interference types, but this text talks about a new type using something called surface plasmon resonance (SPR).
  • The new sensor is very sensitive; it can detect tiny changes in strain by measuring how light behaves when the fiber is stretched.
  • This sensor works really well, with high sensitivity and low costs, making it useful for smart wearables and aerospace applications.

Article Abstract

At present, fiber strain sensors are mainly of the grating type and interference type, while there is relatively little research on fiber surface plasmon resonance (SPR) strain sensors. In this Letter, we propose a highly sensitive fiber SPR strain sensor based on an n-type structure. The strain changes the shape of the fiber n-type structure, causing the transmission mode of light in the fiber to change, thereby changing the SPR incidence angle and causing the SPR resonance valley wavelength to shift, achieving highly sensitive SPR strain sensing. The test results indicate that the strain sensing sensitivity of the proposed sensor reaches 21.33 pm/µε, and two n-type structures are connected in series to obtain a double n-type structure, further enhancing the strain sensing sensitivity to 33.44 pm/µε. This fiber strain sensor has advantages of high sensitivity, low temperature cross talk, strong structural stability, and low production cost, and is expected to become a new solution for wearable intelligent monitoring equipment and strain sensors in the aerospace field.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.500824DOI Listing

Publication Analysis

Top Keywords

spr strain
16
n-type structure
16
strain sensor
12
strain sensors
12
strain sensing
12
strain
10
fiber spr
8
sensor based
8
based n-type
8
fiber strain
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!