Chaotic optical communication encrypts transmitted signals through physical noise; this ensures high security while causing a certain decrease in the signal-to-noise ratio (SNR). Thus, it is necessary to analyze the SNR degradation of decrypted signals after chaotic encryption and the minimum requirements for the SNR of the fiber channel to meet the required bit error rate (BER) performance. Accordingly, an SNR model of decrypted signals for optoelectronic feedback-based chaotic optical communication systems is proposed. Under different channel SNRs, the SNR degradation of 40 Gbit/s phase chaos and intensity chaos models is investigated by simulation and experiment, respectively, with a 15 GHz wideband chaotic carrier. Comparing decrypted signals with original signals, the simulation results show that there is a 2.9 dB SNR degradation for both intensity chaos and phase chaos. Further, in experiments, SNR degradation from 4.5 dB to 5.6 dB, with various channel SNRs for intensity chaos, is analyzed, while there is an SNR degradation from 7.1 dB to 8.3 dB for phase chaos. The simulation and experimental results provide guidance for long-distance transmission chaotic optical communication systems.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.497061DOI Listing

Publication Analysis

Top Keywords

snr degradation
20
chaotic optical
16
optical communication
16
communication systems
12
decrypted signals
12
phase chaos
12
intensity chaos
12
signal-to-noise ratio
8
optoelectronic feedback-based
8
feedback-based chaotic
8

Similar Publications

Improving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI.

J Magn Reson Imaging

January 2025

Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.

Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.

Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.

Study Type: Prospective.

View Article and Find Full Text PDF

Spatially constrained hyperpolarized 13C MRI pharmacokinetic rate constant map estimation using a digital brain phantom and a U-Net.

J Magn Reson

January 2025

UC Berkeley - UCSF Graduate Program in Bioengineering, 1700 4th St, San Francisco, CA 94158, USA; Radiology and Biomedical Imaging, University of California, San Francisco, 1700 4th St, San Francisco, CA 94158, USA.

Fitting rate constants to Hyperpolarized [1-C]Pyruvate (HP C13) MRI data is a promising approach for quantifying metabolism in vivo. Current methods typically fit each voxel of the dataset using a least-squares objective. With these methods, each voxel is considered independently, and the spatial relationships are not considered during fitting.

View Article and Find Full Text PDF

A recent advancement in distributed sensing known as the time-expanded phase-sensitive optical time-domain reflectometry (TE Φ-OTDR) addresses the trade-off between spatial resolution and detection bandwidth, enabling centimeter-scale resolution alongside RF detection bandwidth in the order of MHz. To date, TE Φ-OTDR approaches extract the fiber response from the first Nyquist zone (NZ). In this Letter, we propose a post-processing strategy to enhance the SNR by spectrally averaging different NZs.

View Article and Find Full Text PDF

Spectral Content Effects Study in Non-Contact Resonance Ultrasound Spectroscopy.

Sensors (Basel)

January 2025

Department of Electronics Engineering, Kaunas University of Technology, 51368 Kaunas, Lithuania.

The application of spread-spectrum signals (arbitrary pulse width and position (APWP) sequences) in air-coupled resonant ultrasound spectroscopy is studied. It was hypothesized that spread-spectrum signal optimization should be based on te signal to noise ratio (SNR). Six APWP signal optimization criteria were proposed for this purpose.

View Article and Find Full Text PDF

Frequency-modulated continuous-wave (FMCW) radar is used to extract range and velocity information from the beat signal. However, the traditional joint range-velocity estimation algorithms often experience significant performances degradation under low signal-to-noise ratio (SNR) conditions. To address this issue, this paper proposes a novel approach utilizing the complementary ensemble empirical mode decomposition (CEEMD) combined with singular value decomposition (SVD) to reconstruct the beat signal prior to applying the FFT-Root-MUSIC algorithm for joint range and velocity estimation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!