Predicting mammographic density with linear ultrasound transducers.

Eur J Med Res

Department of Gynecology and Obstetrics, Erlangen University Hospital, University Breast Center for Franconia, Comprehensive Cancer Center European Metropolitan Area Nuremberg (CCC ER-EMN), Friedrich-Alexander University Erlangen-Nuremberg, Universitätsstrasse 21-23, 91054, Erlangen, Germany.

Published: September 2023

Background: High mammographic density (MD) is a risk factor for the development of breast cancer (BC). Changes in MD are influenced by multiple factors such as age, BMI, number of full-term pregnancies and lactating periods. To learn more about MD, it is important to establish non-radiation-based, alternative examination methods to mammography such as ultrasound assessments.

Methods: We analyzed data from 168 patients who underwent standard-of-care mammography and performed additional ultrasound assessment of the breast using a high-frequency (12 MHz) linear probe of the VOLUSON 730 Expert system (GE Medical Systems Kretztechnik GmbH & Co OHG, Austria). Gray level bins were calculated from ultrasound images to characterize mammographic density. Percentage mammographic density (PMD) was predicted by gray level bins using various regression models.

Results: Gray level bins and PMD correlated to a certain extent. Spearman's ρ ranged from - 0.18 to 0.32. The random forest model turned out to be the most accurate prediction model (cross-validated R, 0.255). Overall, ultrasound images from the VOLUSON 730 Expert device in this study showed limited predictive power for PMD when correlated with the corresponding mammograms.

Conclusions: In our present work, no reliable prediction of PMD using ultrasound imaging could be observed. As previous studies showed a reasonable correlation, predictive power seems to be highly dependent on the device used. Identifying feasible non-radiation imaging methods of the breast and their predictive power remains an important topic and warrants further evaluation. Trial registration 325-19 B (Ethics Committee of the medical faculty at Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Germany).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10537934PMC
http://dx.doi.org/10.1186/s40001-023-01327-9DOI Listing

Publication Analysis

Top Keywords

mammographic density
16
gray level
12
level bins
12
predictive power
12
voluson 730
8
730 expert
8
ultrasound images
8
pmd correlated
8
ultrasound
6
predicting mammographic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!