A 76-year-old female with severe symptomatic aortic stenosis underwent cardiac CT angiography imaging. Severe calcification of the ascending aorta (porcelain aorta) (Figures 1A and 1B) precluded surgical aortic valve replacement. The aortic annular area, perimeter, and diameter were 372 mm2, 68.5 mm, and 20 mm, respectively. Transcatheter aortic valve replacement (TAVR) was performed with direct implantation of a 23 mm Sapien S3 valve (Edwards Lifesciences). The valve was delivered via the right femoral artery and a pigtail catheter was delivered to the aortic root via the left femoral artery. The balloon ruptured during valve implantation (Video).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.25270/jic/22.00351 | DOI Listing |
Indian J Thorac Cardiovasc Surg
February 2025
Department of Cardiovascular Surgery, Abderrahmen Mami Pneumology and Phthisiology Hospital, Ariana, Tunisia.
Infective endocarditis (IE) in children is a rare entity which presents a high rate of events during follow-up. Congenital heart disease, i particular ventricular septal defect (VSD), is the main predisposing condition to IE at those ages. The long-term risk of IE is of concern and whose follow-up can be complicated by a relapse of IE and reintervention.
View Article and Find Full Text PDFJACC Case Rep
January 2025
Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA.
Paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR) is an established complication, albeit rarely associated with hemolytic anemia. This report details 3 cases of significant hemolytic anemia attributed to TAVR-induced PVL, each with distinct clinical presentations and manifestations. These cases underscore the diverse and occasionally subtle clinical presentation of aortic PVL-associated hemolytic anemia.
View Article and Find Full Text PDFJACC Case Rep
January 2025
Interventional Cardiology Section, Division of Cardiovascular Medicine, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA.
Aneurysms of the interventricular membranous septum are a rare anatomical feature that can be detected incidentally on computed tomography or echocardiography. Such aneurysms can pose challenges in the treatment of patients with aortic valve stenosis. A case series of 2 patients with membranous septal aneurysms treated successfully with current-generation balloon-expandable and self-expanding transcatheter heart valves is presented here.
View Article and Find Full Text PDFJACC Case Rep
December 2024
Department of Nuclear Medicine, Hospital Clínico San Carlos, Madrid, Spain.
A 75-year-old patient with a history of mitral and aortic valve replacement surgery 7 years ago, presented with progressive dyspnea. Transesophageal echocardiogram showed a mass suggestive of bioprosthetic mitral valve thrombosis. We present the investigation process using imaging, surgical findings, nuclear medicine, and histopathology that result in the diagnosis of cardiac angiosarcoma.
View Article and Find Full Text PDFJACC Case Rep
December 2024
Department of Cardiology, Valdivia Hospital, School of Medicine Austral University, Valdivia, Chile.
This case presents a 69-year-old woman with a previous history of arterial hypertension. A transthoracic echocardiogram was requested in the context of shortness of breath with great exercise. Incidentally, at the aortic valve level, a mobile mass suggestive of papillary fibroelastoma was visualized.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!