Design and Mixing Analysis of a Passive Micromixer Based on Curly Baffles.

Micromachines (Basel)

School of Mechanical Engineering, Yeungnam University, 280 Daehak-Ro, Gyeongsan 38541, Gyeongbuk, Republic of Korea.

Published: September 2023

A novel passive micromixer based on curly baffles is proposed and optimized through the signal-to-noise analysis of various design parameters. The mixing performance of the proposed design was evaluated across a wide Reynolds number range, from 0.1 to 80. Through the analysis, the most influential parameter was identified, and its value was found to be constant regardless of the mixing mechanism. The optimized design, refined using the signal-to-noise analysis, demonstrated a significant enhancement of mixing performance, particularly in the low Reynolds number range (Re< 10). The design set obtained at the diffusion dominance range shows the highest degree of mixing (DOM) in the low Reynolds number range of Re< 10, while the design set optimized for the convection dominance range exhibited the least pressure drop across the entire Reynolds number spectrum (Re< 80). The present design approach proved to be a practical tool for identifying the most influential design parameter and achieving excellent mixing and pressure drop characteristics. The enhancement is mainly due to the curvature of the most influential design parameter.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10535907PMC
http://dx.doi.org/10.3390/mi14091795DOI Listing

Publication Analysis

Top Keywords

reynolds number
16
number range
12
re< design
12
design
9
passive micromixer
8
micromixer based
8
based curly
8
curly baffles
8
signal-to-noise analysis
8
mixing performance
8

Similar Publications

Importance: Patients undergoing unplanned abdominal surgical procedures are at increased risk of surgical site infection (SSI). It is not known if incisional negative pressure wound therapy (iNPWT) can reduce SSI rates in this setting.

Objective: To evaluate the effectiveness of iNPWT in reducing the rate of SSI in adults undergoing emergency laparotomy with primary skin closure.

View Article and Find Full Text PDF

Towards a standard application of the Reynolds number in studies of aquatic animal locomotion.

J Exp Biol

January 2025

Department of Physics and Engineering Science, Coastal Carolina University, Conway, SC 29528, USA.

Nondimensional groups of measured quantities enable comparison between measurements of animals under different conditions and comparison between species. One of the most used such group is the Reynolds number, which compares inertial and viscous contributions to forces on swimming animals. This group includes two quantities that are chosen by the researcher: a typical length and speed.

View Article and Find Full Text PDF

The stability of kinetic-level convection cells (wherein the magnitude of macroscopic and microscopic velocities are of same order) is studied in a two-dimensional Yukawa liquid under the effect of microscopic velocity perturbations. Our numerical experiments demonstrate that for a given system aspect ratio β viz., the ratio of system length [Formula: see text] to its height [Formula: see text] and number of convective rolls initiated [Formula: see text], the fate of the convective cells is decided by [Formula: see text].

View Article and Find Full Text PDF

Continuous Production of Docetaxel-Loaded Nanostructured Lipid Carriers Using a Coaxial Turbulent Jet Mixer with Heating System.

Molecules

January 2025

Department of Electronic Materials, Devices, and Equipment Engineering, Soonchunhyang University, 22 Soonchunhyang-ro, Shinchang-myeon, Asan-si 31538, Chungcheongnam-do, Republic of Korea.

The continuous synthesis of nanoparticles (NPs) has been actively studied due to its great potential to produce NPs with reproducible and controllable physicochemical properties. Here, we achieved the high throughput production of nanostructured lipid carriers (NLCs) using a coaxial turbulent jet mixer with an added heating system. This device, designed for the crossflow of precursor solution and non-solvent, combined with the heating system, efficiently dissolves solid lipids and surfactants.

View Article and Find Full Text PDF

In recent years, microfluidics has emerged as an interdisciplinary field, receiving significant attention across various biomedical applications. Achieving a noticeable mixing of biofluids and biochemicals at laminar flow conditions is essential in numerous microfluidics systems. In this research work, a new kind of micromixer design integrated with an Archimedes screw is designed and investigated using numerical simulation and experimental approaches.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!