Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The influence of cuff inflations on night-time measurements during 24 h ambulatory blood pressure (BP) measurements is unknown. We investigated the potential effect of cuff inflations on sleep parameters using measurements taken simultaneously with a cuffless device using pulse-transit-time (PTT). On the first day of measurement, standard cuff-based 24 h BP and cuffless measurements were simultaneously performed on the right and left arms (CUFF/PTT-D). In this experiment, 1-2 days after the first measurement, the cuffless device was worn alone (PTT-D). Only data from the cuffless device were analyzed. The following mean sleep parameters were analyzed: mean systolic and diastolic BP, arousals, sleep efficiency, total arousals, arousal per hour, and desaturations. In total, 21 individuals were prospectively enrolled. The mean (SD) age was 47 (±15) years, and 57% were female. The mean systolic asleep BP during CUFF/PTT-D and during PTT-D were 131 (±21) and 131 (±26) mmHg, respectively. The mean diastolic asleep BP values during CUFF/PTT-D and during PTT-D were 80 (±14) and 84 (±14) mmHg, respectively ( = 0.860, = 0.100, respectively). Systolic and diastolic asleep mean difference was 0.1 (±18.0) and -3.6 (±9.8) mmHg, respectively. There were significantly more total arousals during PTT-D ( = 0.042). There were no significant differences seen in sleep efficiency ( = 0.339) or desaturations ( = 0.896) between the two measurement periods. We could not show any significant impact from cuff inflations during sleep, as documented by PTT-D measurements.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10529092 | PMC |
http://dx.doi.org/10.3390/diagnostics13182874 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!