A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Learnability of Thyroid Nodule Assessment on Ultrasonography: Using a Big Data Set. | LitMetric

Objective: The aims of the work described here were to evaluate the learnability of thyroid nodule assessment on ultrasonography (US) using a big data set of US images and to evaluate the diagnostic utilities of artificial intelligence computer-aided diagnosis (AI-CAD) used by readers with varying experience to differentiate benign and malignant thyroid nodules.

Methods: Six college freshmen independently studied the "learning set" composed of images of 13,560 thyroid nodules, and their diagnostic performance was evaluated after their daily learning sessions using the "test set" composed of images of 282 thyroid nodules. The diagnostic performance of two residents and an experienced radiologist was evaluated using the same "test set." After an initial diagnosis, all readers once again evaluated the "test set" with the assistance of AI-CAD.

Results: Diagnostic performance of almost all students increased after the learning program. Although the mean areas under the receiver operating characteristic curves (AUROCs) of residents and the experienced radiologist were significantly higher than those of students, the AUROCs of five of the six students did not differ significantly compared with that of the one resident. With the assistance of AI-CAD, sensitivity significantly increased in three students, specificity in one student, accuracy in four students and AUROC in four students. Diagnostic performance of the two residents and the experienced radiologist was better with the assistance of AI-CAD.

Conclusion: A self-learning method using a big data set of US images has potential as an ancillary tool alongside traditional training methods. With the assistance of AI-CAD, the diagnostic performance of readers with varying experience in thyroid imaging could be further improved.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2023.08.026DOI Listing

Publication Analysis

Top Keywords

diagnostic performance
20
big data
12
data set
12
"test set"
12
residents experienced
12
experienced radiologist
12
learnability thyroid
8
thyroid nodule
8
nodule assessment
8
assessment ultrasonography
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!