Increasing Performance of Spiral-Wound Modules (SWMs) by Improving Stability against Axial Pressure Drop and Utilising Pulsed Flow.

Membranes (Basel)

Food and Bioprocess Engineering, TUM School of Life Sciences, Technical University of Munich, Weihenstephaner Berg 1, 85354 Freising, Germany.

Published: September 2023

Spacer-induced flow shadows and limited mechanical stability due to module construction and geometry are the main obstacles to improving the filtration performance and cleanability of microfiltration spiral-wound membranes (SWMs), applied to milk protein fractionation in this study. The goal of this study was first to improve filtration performance and cleanability by utilising pulsed flow in a modified pilot-scale filtration plant. The second goal was to enhance membrane stability against module deformation by flow-induced friction in the axial direction ("membrane telescoping"). This was accomplished by stabilising membrane layers, including spacers, at the membrane inlet by glue connections. Pulsed flow characteristics similar to those reported in previous lab-scale studies could be achieved by establishing an on/off bypass around the membrane module, thus enabling a high-frequency flow variation. Pulsed flow significantly increased filtration performance (target protein mass flow into the permeate increased by 26%) and cleaning success (protein removal increased by 28%). Furthermore, adding feed-side glue connections increased the mechanical membrane stability in terms of allowed volume throughput by ≥100% compared to unmodified modules, thus allowing operation with higher axial pressure drops, flow velocities and pulsation amplitudes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10535890PMC
http://dx.doi.org/10.3390/membranes13090791DOI Listing

Publication Analysis

Top Keywords

pulsed flow
16
filtration performance
12
axial pressure
8
utilising pulsed
8
flow
8
stability module
8
performance cleanability
8
membrane stability
8
glue connections
8
membrane
5

Similar Publications

Pulsed-Current Operation Enhances HO Production on a Boron-Doped Diamond Mesh Anode in a Zero-Gap PEM Electrolyzer.

ChemSusChem

January 2025

Department of Chemical Engineering, MESA+ Institute for Nanotechnology, Faculty of Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB, Enschede, The, Netherlands.

A niobium (Nb) mesh electrode was coated with boron-doped diamond (BDD) using chemical vapor deposition in a custom-built hot-filament reactor. The BDD-functionalized mesh was tested in a zero-gap electrolysis configuration and evaluated for the anodic formation of HO by selective oxidation of water, including the analysis of the effects on Faradaic efficiency towards HO (FEH2O2) induced by pulsed electrolysis. A low electrolyte flow rate (V⋅) was found to result in a relatively high concentration of HO in single-pass electrolysis experiments.

View Article and Find Full Text PDF

Background: Individuals with spinal cord injury (SCI) commonly have autonomic dysreflexia (AD) with increased sympathetic activity. After SCI, individuals have decreased baroreflex sensitivity and increased vascular responsiveness.

Objective: To evaluate the relationship between baroreflex and blood vessel sensitivity with AD symptoms.

View Article and Find Full Text PDF

Can fast wall shear stress computation predict adverse cardiac events in patients with intermediate non-flow limiting stenoses?

Atherosclerosis

December 2024

Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, London, UK; Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London, London, UK. Electronic address:

Background And Aims: Coronary angiography-derived wall shear stress (WSS) may enable identification of vulnerable plaques and patients. A new recently introduced software allows seamless three-dimensional quantitative coronary angiography (3D-QCA) reconstruction and WSS computation within a single user-friendly platform carrying promise for clinical applications. This study examines for the first time the efficacy of this software in detecting vulnerable lesions in patients with intermediate non-flow limiting stenoses.

View Article and Find Full Text PDF

Little is known about the effects of sodium-glucose co-transporter 2 inhibitors (SGLT2i) on atherosclerosis. We aimed to determine if a 90-day intake of Dapagliflozin could improve atherosclerosis biomarkers (namely endothelial function assessed by flow-mediated dilatation [FMD] and carotid intima-media thickness [CIMT]) in diabetic and non-diabetic acute coronary syndrome (ACS) patients when initiated in the early in-hospital phase. ATH-SGLT2i was a prospective, single-center, observational trial that included 113 SGLT2i naive patients who were admitted for ACS and who were prescribed Dapagliflozin at a fixed dose of 10 mg during their hospital stay for either type 2 diabetes or for heart failure.

View Article and Find Full Text PDF

Background: High-flow nasal cannula (HFNC) therapy has developed as a valuable tool for respiratory support in pediatric critical care. It offers an intermediate level of support between traditional low-flow oxygen and non-invasive ventilation (NIV). Studies suggest its effectiveness in improving oxygen delivery, work of breathing, and secretion clearance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!