The use of self-collected capillary blood has several advantages over phlebotomy, as such finger-prick testing is rapidly becoming accepted as a routine sample type for adults. However, there is limited evidence that venous and capillary serum is comparable for many analytes. This study aimed to determine whether capillary samples could offer an alternative sampling method to venous samples for the assessment of serum creatinine using the enzymatic method and if this analyte was stable in unspun capillary blood for 3 days. Matched capillary and venous blood samples were collected from 48 patients for the determination of serum creatinine, one set being processed on day zero, the other set being stored at ambient temperature and then processed on day three. Self-collected capillary blood was compared with phlebotomist-collected venous samples. Serum creatinine concentrations from venous and capillary blood samples taken on day zero were compared to concentrations in capillary blood from day three. Data produced showed serum creatinine concentrations from capillary and venous serum to be comparable. It is believed that this is the first published study to determine if self-collected capillary blood sampling is an acceptable alternative to venous sampling for the measurement of serum creatinine concentration; our data indicates that there is no significant difference in results from unspun venous and capillary blood stored at room temperature for at least 3 days compared to venous blood tested on the same day of collection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10519179PMC
http://dx.doi.org/10.3389/bjbs.2023.11402DOI Listing

Publication Analysis

Top Keywords

capillary blood
28
serum creatinine
24
capillary
12
capillary venous
12
venous blood
12
self-collected capillary
12
venous capillary
12
venous
10
blood
10
serum
8

Similar Publications

Preferential Sites of Retinal Capillary Occlusion in Sickle Cell Disease.

Invest Ophthalmol Vis Sci

January 2025

Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, United States.

Purpose: To assess the preferential sites of retinal capillary occlusion at the parafovea in patients with sickle cell disease (SCD) using optical coherence tomography angiography (OCT-A).

Methods: OCT-A scans from 107 patients with SCD and 51 race-matched unaffected controls were obtained using a commercial spectral domain-OCT system. At least eight sequential 3 × 3 mm scans centered at the fovea were acquired and averaged for image analysis.

View Article and Find Full Text PDF

Background: A proper placentation is required for establishment and continuity of pregnancy. In sheep, placentomes are unique structures that enable nutrition and gas exchange between the mother and the foetus. Although placentomes are dynamic formations, there is limited knowledge of changes in placentomes during pregnancy.

View Article and Find Full Text PDF

Aims: Physiological changes during pregnancy can infuence the performance of blood glucose meters. This study aimed to evaluate the analytical and clinical accuracy of glucose meters in pregnant women with hyperglycaemia.

Materials And Methods: Glucose was measured by four commonly used meters among consecutive women with diabetes in pregnancy.

View Article and Find Full Text PDF

The aim of this study was to investigate the locational distribution and potential mechanisms of retinal hemorrhages in newborns using fundus photography. A retrospective analysis of 98 consecutive newborns with retinal hemorrhages in at least one eye and 30 control newborns without retinal hemorrhages after uneventful delivery was conducted. Retinal hemorrhages were diagnosed and characterized using fundus photography and indirect ophthalmoscopy.

View Article and Find Full Text PDF

Myocardial ischemia-reperfusion injury increases myocardial microvascular permeability, leading to enhanced microvascular filtration and interstitial fluid accumulation that is associated with greater microvascular obstruction and inadequate myocardial perfusion. A burst of reactive oxygen species and inflammatory mediators during reperfusion causes myosin light chain kinase (MLCK)-dependent endothelial hyperpermeability, which is considered a preventable cause of reperfusion injury. In the present study, a single intravenous injection of MLCK peptide inhibitor PIK7 (2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!