A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Video Documentation as a Measure of Written Documentation Accuracy in Emergency Medical Service Field Intubations. | LitMetric

Introduction: Quality improvement (QI) is a major focus of all departments and fields of health care, including emergency medical services. The chaotic and rapidly evolving atmosphere in which paramedics must practice can lead to inconsistency between what is documented and the actual events. This leads to difficulty when trying to evaluate the practitioners and when implementing a QI program. In this study, we evaluated the prevalence of discrepancy between the video and written record for Rapid Sequence Intubation (RSI) performed in the field as a demonstration of the utility of video documentation in QI.

Methods: We used a systematic retrospective chart review to compare written with video documentation in 100 consecutive prehospital RSI encounters in a single EMS agency.

Results: Of the patient care records (PCRs), only 6% matched the video record for all quality measures tracked. The largest reason for the discrepancy was in the time required to intubate (58%) whether LEMON was evaluated (42%), total number of intubation attempts (36%), first attempt success (24%), BVM used (18%), and whether an airway introducer device was used (12%).

Conclusion: Written documentation is inaccurate compared to video documentation when used as a quality improvement process for EMS prehospital RSI encounters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10519629PMC
http://dx.doi.org/10.36518/2689-0216.1183DOI Listing

Publication Analysis

Top Keywords

video documentation
16
written documentation
8
emergency medical
8
quality improvement
8
prehospital rsi
8
rsi encounters
8
video
6
documentation
5
documentation measure
4
written
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!