Sci Rep
Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Published: September 2023
Percutaneous drains have provided a minimally invasive way to treat a wide range of disorders from abscess drainage to enteral feeding solutions to treating hydronephrosis. These drains suffer from a high rate of dislodgement of up to 30% resulting in emergency room visits, repeat hospitalizations, and catheter repositioning/replacement procedures, which incur significant morbidity and mortality. Using ex vivo and in vivo models, a force body diagram was utilized to determine the forces experienced by a drainage catheter during dislodgement events, and the individual components which contribute to drainage catheter securement were empirically collected. Prototypes of a skin level catheter securement and valved quick release system were then developed. The system was inspired by capstans used in boating for increasing friction of a line around a central spool and quick release mechanisms used in electronics such as the Apple MagSafe computer charger. The device was tested in a porcine suprapubic model, which demonstrated the effectiveness of the device to prevent drain dislodgement. The prototype demonstrated that the miniaturized versions of technologies used in boating and electronics industries were able to meet the needs of preventing dislodgement of patient drainage catheters.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10522644 | PMC |
http://dx.doi.org/10.1038/s41598-023-37850-2 | DOI Listing |
Ann Emerg Med
January 2025
Children's Hospital of Eastern Ontario Research Institute, Ottawa, ON, Canada; Department of Pediatrics, Children's Hospital of Eastern Ontario, University of Ottawa, Ottawa, ON, Canada. Electronic address:
Study Objective: The peripheral intravenous catheter (IV) is the most common and painful invasive medical device in acute care settings. Our objective was to determine whether adding skin glue to secure IVs reduced catheter failure rate in children.
Methods: We conducted a randomized controlled trial in a tertiary-care pediatric emergency department (ED).
Nagoya J Med Sci
November 2024
Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Selecting an appropriate microcatheter tip shape for paraclinoid aneurysms is difficult. Therefore, we devised an original simple and uniform three-dimensional (3D) spiral-shaping method of microcatheter and validated the characteristics and usefulness of this method for coil embolization of paraclinoid aneurysms using patient-specific silicone models. These silicone models were produced based on clinical data from four patients with four paraclinoid aneurysms that underwent endovascular treatment using the 3D spiral-shaping method.
View Article and Find Full Text PDFZhonghua Wei Zhong Bing Ji Jiu Yi Xue
December 2024
Department of Critical Care Medicine, Provincial Hospital Affiliated to Shandong First Medical University, Jinan 250021, Shandong, China. Corresponding author: Zhang Jicheng, Email:
Objective: To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.
Methods: The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.
J Med Syst
January 2025
Department of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands.
This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements.
View Article and Find Full Text PDFEuropace
December 2024
Department of Cardiology, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700 RB Groningen, The Netherlands.
Atrial fibrillation (AF) remains the most common cardiac arrhythmia worldwide and is associated with significant morbidity and mortality. The European Society of Cardiology (ESC)/European Association for Cardio-Thoracic Surgery (EACTS) have recently released the 2024 guidelines for the management of AF. This review highlights 10 novel aspects of the ESC/EACTS 2024 Guidelines.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!
© LitMetric 2025. All rights reserved.