A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Synthesis of uniformly dispersed FeTiO nanodisks: a sensitive photoelectrochemical sensor for glucose monitoring in human blood serum. | LitMetric

Synthesis of uniformly dispersed FeTiO nanodisks: a sensitive photoelectrochemical sensor for glucose monitoring in human blood serum.

Analyst

Institut für Quanten Materialien und Technologien, Karlsruher Institut für Technologie, Hermann-v.-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.

Published: October 2023

A novel photoelectrochemical (PEC) sensor was constructed, using FeTiO nanodisks under visible-light irradiation, for the determination of glucose in human blood serum. The uniformly dispersed FeTiO nanodisks were synthesized for the first time by an ion exchange method and subsequent heat treatment. As excellent catalysts, the FeTiO nanodisks can directly catalyze the oxidation of glucose to produce current in the absence of glucose oxidase. Compared with commercial TiO, the FeTiO nanodisks exhibit better activity in the electrocatalytic oxidation of glucose and can generate a photocurrent as a signal for glucose detection. The PEC sensor shows a wide linear range (4 μM-10 mM), a low limit of detection (0.588 μM) and a super sensitivity of 2653 μA mM cm, which are much better than similar configurations reported previously. This PEC sensor has been successfully used to monitor glucose in human blood serum. Moreover, this PEC glucose sensor based on FeTiO nanodisks possesses great potential for application in point-of-care clinical diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3an01265dDOI Listing

Publication Analysis

Top Keywords

fetio nanodisks
24
human blood
12
blood serum
12
pec sensor
12
uniformly dispersed
8
dispersed fetio
8
glucose
8
glucose human
8
oxidation glucose
8
fetio
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!