Objectives: To evaluate the clinical performance of monolithic zirconia restorations with feather-edge margins fabricated by digital impressions.
Materials And Methods: All participants that present monolithic zirconia restorations with feather-edge margins realized with digital workflow were evaluated during scheduled periodontal maintenance between February and September 2022 according to predetermined inclusion criteria. Clinical performance was assessed using the modified USPHS and periodontal parameters. Overall survival was calculated for monolithic zirconia restorations. Technical and biologic complications were reported. Descriptive statistical analysis and life-table analyses were performed for all data.
Results: A total of 1472 monolithic zirconia FDPs (1279 on abutments and 193 on pontics) placed in 1189 patients (982 males and 490 females) from February 2017 to September 2020 were analyzed. The mean follow-up was 44 months (range 36-61 months), and the overall survival rate was 98.5%. There were 931 single crowns, 96 were 3-unit FDPs, 33 were 4-unit FDPs, 11 were 5-unit FDPs, and 6-unit FDPs. Three single crowns had irreparable cracks, and 6 single crowns and one 4-unit FDP were fractured. One 3-unit FDP failed due to tooth fracture and 5 single crowns failed due to endodontic failure. The loss of retention was noted in 25 monolithic zirconia FDPs and hypersensitivity in 44 single crowns. Biologic complications were uncommon.
Conclusions: Based on the results and its limitations, the monolithic zirconia FPDs and digital impressions represent a favorable prosthetic treatment similar to that reported with other margin designs CLINICAL RELEVANCE: Monolithic zirconia restorations on vertical-margin abutments fabricated using a digital workflow demonstrate excellent clinical performance. The digital clinical workflow without the use of a cast means a reduction in costs, steps, and operating time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00784-023-05262-1 | DOI Listing |
J Prosthodont Res
January 2025
Department of Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, UAE.
Purpose: This retrospective clinical study aimed to evaluate the clinical outcomes of surveyed monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia crowns for abutment teeth in removable partial dentures (RPDs).
Methods: Patients who received monolithic surveyed zirconia crowns were clinically examined. The crowns were examined according to the modified United States Public Health Service criteria, and Kaplan-Meier survival was determined.
Dent Mater
January 2025
Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru, SP 17012-901, Brazil.
Objectives: To characterize two experimental zirconia bilayer materials compared to their monolithic controls, before and after hydrothermal aging.
Methods: Commercial zirconia powders were utilized to fabricate two bilayer materials: 3Y-TZP+ 5Y-PSZ (3Y+5Y/BI) and 4Y-PSZ+ 5Y-PSZ (4Y+5Y/BI), alongside control groups 3Y-TZP (3Y/C), 4Y-PSZ (4Y/C), and 5Y-PSZ (5Y/C). Compacted specimens were sintered (1550 °C- 2 h, 3 °C/min), and half of them underwent hydrothermal aging (134 °C-20h, 2.
J Dent
January 2025
Senior Research and Teaching Assistant, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland. Electronic address:
Objectives: A new abutment-free implant connection allows for direct screwing of FDPs on implants to avoid complications caused by cement rests or screw loosening, which may affect to screw torque and load distribution. The objective of this study was to test the initial (Fi) and final failure (Ff) loads and torque changes of abutment-free monolithic zirconia CAD-CAM fixed dental prostheses (FDPs) compared to titanium FDPs on different abutment designs.
Methods: Three-unit screw-retained FDPs (n = 50) on two implants (n = 100) were divided into groups (n = 10) based on the implant-abutment connection and material of the supra-structure: (1) abutment-free monolithic CAD-CAM zirconia FDP (Abut-free-Zr), (2) abutment-free veneered titanium FDPs (Abut-free-Ti), (3) monolithic zirconia FDPs with titanium base abutments (Zr-Ti-Base), (4) monolithic zirconia FDPs on multi-unit abutments (Zr-MU), (5) veneered titanium FDP on multi-unit abutments (Ti-MU).
J Prosthodont
January 2025
Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Lagoa Nova, Natal, Brazil.
Purpose: To assess the impact of staining and multiple firings on the mechanical, optical, and surface characteristics of zirconia-containing lithium silicate ceramics (ZLS).
Materials And Methods: Ninety ZLS discs (Suprinity, VITA Zahnfabrick) were divided according to the "Number of firings" protocol: Ctr-control, no characterization; SC-single firing cycle (for characterization, crystallization and staining simultaneously); and DC-double firing cycle (crystallization firing cycle was performed separately from the staining firing). Extrinsic pigmentation was performed to replicate the characterization of a monolithic restoration.
J Oral Implantol
January 2025
Department of Orthodontics and Pedodontics, Faculty of Dentistry, Van Lang University, Ho Chi Minh City, Vietnam.
The reverse scan technique offers several advantages, such as improvements of accuracy and visibility of critical anatomical structures, minimizing chair time, and providing better patient comfort. This was a case report successfully employing the reverse scan technique. A 72-year-old male patient desired to restore his teeth in both jaws, as he experienced difficulty eating and had never worn dentures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!