Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: We aimed to investigate the effect of the use of electronic home spirometry in children with cystic fibrosis (CF) on 1-year FEV (% predicted, pp) change.
Methods: This is a randomised, one-year prospective study including children with CF between 6 and 18 years of age. Subjects were randomised into home spirometry group (HSG) and usual care group (UCG). Children in HSG performed two pulmonary function tests (PFT) per week. Data regarding acute pulmonary exacerbations (PEx) was obtained from patients' records. At baseline and 12th month, health related quality of life questionnaire for CF patients (CFQ-R) and lung clearance index (LCI) were performed.
Results: Sixty children were recruited with a median (IQR) age of 13.3 (11.4-15.4) years. Absolute change in FEVpp from baseline to 12th month as median (IQR) was +1% (-6.75-9.75) in HSG and -2.50% (-7.50-3.25) in UCG (p = 0.10). Sensitivity analysis including only adherent children in HSG (n = 22), yielded an increase of 5% (-3.50-12) in HSG and a decrease of 2.50% (-7.50-3.25) in UCG (p = 0.009). A total of 29 (96.7%) subjects in HSG and 23 (76.7%) in UCG had PEx (p = 0.05). Absolute change in median (IQR) LCI from baseline to the 12th month was -1.6 [-2.9-0] (p<0.001) in HSG and -1.5 [-2.8-(-0.6)] (p<0.001) in UCG (p = 0.94). There was a significant increase in the social domain of the CFQ-R in HSG (from 59.1 to 76.2, p = 0.01).
Conclusions: Electronic home monitoring of children with CF by spirometry may result in improvement in lung function.