A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A case of laparoscopic sigmoidectomy using thermography for colonic blood flow assessment. | LitMetric

Background: Indocyanine green (ICG) fluorescence imaging is widely used in gastrointestinal surgery and is considered useful for reducing anastomotic leakage; however, because ICG remains in the tissue for a certain amount of time, we occasionally must re-evaluate colonic blood flow over a short time period during surgery. Herein, we verify the usefulness of thermography (TG) for evaluating colonic blood flow in a patient who underwent a laparoscopic sigmoidectomy for sigmoid colon cancer.

Case Presentation: The patient is 43-year-old man who underwent laparoscopic resection of the sigmoid colon for colon cancer. After vascular treatment of the colonic mesentery, ICG/TG identified the boundary between ischemic and non-ischemic colon tissues. An additional 2 cm of colonic mesentery was resected because of the presence of a diverticulum noted at the intended site of oral anastomosis when attaching the anvil head. After additional vascular treatment of the colonic mesentery and administration of ICG, fluorescence was observed in the colon; however, TG identified the zone of the temperature transition on the surface of the colonic mesentery, even after additional colonic mesentery resection in the same region as previously observed. This zone was used as the cut-off line. There were no complications, such as anastomotic leakage, after the surgery.

Conclusion: Although accumulation of similar cases is necessary, TG has the potential for use as an auxiliary diagnostic tool in clinical practice. TG can depict the presence or absence of blood flow based on surface temperature without the use of imaging agents, and is inexpensive and easy to perform.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10519892PMC
http://dx.doi.org/10.1186/s40792-023-01752-2DOI Listing

Publication Analysis

Top Keywords

colonic mesentery
20
blood flow
16
colonic blood
12
laparoscopic sigmoidectomy
8
colonic
8
icg fluorescence
8
anastomotic leakage
8
underwent laparoscopic
8
sigmoid colon
8
vascular treatment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!