Arguably, diabetes mellitus is one of the best quantified human conditions. In the past 50 years, the metabolic monitoring technologies progressed from occasional assessment of average glycemia via HbA, through episodic blood glucose readings, to continuous glucose monitoring (CGM) producing data points every few minutes. The high-temporal resolution of CGM data enabled increasingly intensive treatments, from decision support assisting insulin injection or oral medication, to automated closed-loop control, known as the "artificial pancreas." Throughout this progress, mathematical models and computer simulation of the human metabolic system became indispensable for the technological progress of diabetes treatment, enabling every step, from assessment of insulin sensitivity via the now classic Minimal Model of Glucose Kinetics, to in silico trials replacing animal experiments, to automated insulin delivery algorithms. In this review, we follow these developments, beginning with the Minimal Model, which evolved through the years to become large and comprehensive and trigger a paradigm change in the design of diabetes optimization strategies: in 2007, we introduced a sophisticated model of glucose-insulin dynamics and a computer simulator equipped with a "population" of N = 300 in silico "subjects" with type 1 diabetes. In January 2008, in an unprecedented decision, the Food and Drug Administration (FDA) accepted this simulator as a substitute to animal trials for the pre-clinical testing of insulin treatment strategies. This opened the field for rapid and cost-effective development and pre-clinical testing of new treatment approaches, which continues today. Meanwhile, animal experiments for the purpose of designing new insulin treatment algorithms have been abandoned.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10658679 | PMC |
http://dx.doi.org/10.1177/19322968231195081 | DOI Listing |
PLoS One
January 2025
School of Human Nutrition, McGill University, Montreal, Québec, Canada.
Objective: Managing blood glucose levels is challenging for elite athletes with type 1 diabetes (T1D) as competition can cause unpredictable fluctuations. While fear of hypoglycemia during physical activity is well documented, research on hyperglycemia-related anxiety (HRA) is limited. HRA refers to the heightened fear that hyperglycemia-related symptoms will impair functioning.
View Article and Find Full Text PDFPLoS One
January 2025
Population Health Research Institute, St George's, University of London, London, United Kingdom.
Aims: Type 2 diabetes (T2D) is more common in certain ethnic groups. This systematic review compares mortality risk between people with T2D from different ethnic groups and includes recent larger studies.
Methods: We searched nine databases using PRISMA guidelines (PROSPERO CRD42022372542).
Eur J Heart Fail
January 2025
Department of Medicine, University of Chicago Medicine, Chicago, IL, USA.
Aims: This post hoc analysis aimed to assess the efficacy and safety of the non-steroidal mineralocorticoid receptor antagonist finerenone by baseline diuretic use in FIDELITY, a pre-specified pooled analysis of the phase III trials FIDELIO-DKD and FIGARO-DKD.
Methods And Results: Eligible patients with type 2 diabetes (T2D) and chronic kidney disease (CKD; urine albumin-to-creatinine ratio [UACR] ≥30-<300 mg/g and estimated glomerular filtration rate [eGFR] ≥25-≤90 ml/min/1.73 m, or UACR ≥300-≤5000 mg/g and eGFR ≥25 ml/min/1.
J Manag Care Spec Pharm
January 2025
Joslin Diabetes Center, Sequel Med Tech, Boston, MA.
Background: Type 2 diabetes (T2D) causes increased health care resource utilization (HCRU) and costs in the United States. People with T2D are more likely to have atherosclerotic cardiovascular disease (ASCVD), which is associated with significant morbidity and mortality. Medical associations recommend cardioprotective antidiabetic medications, including sodium-glucose cotransporter-2 inhibitors (SGLT2is) and glucagon-like peptide 1 receptor agonists (GLP-1 RAs), to reduce the risk of cardiovascular events in patients with T2D with established, or a high risk of, ASCVD, but not all eligible patients receive these medications.
View Article and Find Full Text PDFJ Manag Care Spec Pharm
January 2025
Abbott Diabetes Care, Mississauga, Ontario, Canada.
Background: Both glucagon-like peptide 1 receptor agonists (GLP-1 RAs) and continuous glucose monitoring (CGM) have been shown to improve glycated hemoglobin A1c (A1c) levels among patients with type 2 diabetes mellitus (T2DM). Recently, a US real-world study found statistically significant improvements in A1c levels among patients using GLP-1 RA and a CGM device, compared with a matched cohort receiving only GLP-1 RA.
Objectives: To assess the cost-effectiveness from a US payer perspective of initiating CGM (FreeStyle Libre Systems) in people living with T2DM using a GLP-1 RA therapy, compared with GLP-1 RA alone.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!