The Diagnostic Performance of Fecal Immunochemical Tests for Detecting Advanced Neoplasia at Surveillance Colonoscopy.

Clin Gastroenterol Hepatol

Cancer Research, Flinders Health and Medical Research Institute, Bedford Park, South Australia, Australia; Department of Gastroenterology and Hepatology, Flinders Medical Centre, Southern Adelaide Local Health Network, South Australia, Australia. Electronic address:

Published: April 2024

Background & Aims: An increasing burden on health care resources has resulted in a backlog of individuals requiring colonoscopy, with delays in surveillance possibly detrimental for individuals at increased risk of colorectal cancer (CRC). This study investigated the use of a 2-sample fecal immunochemical test (FIT) to establish those most likely to have advanced neoplasia (AN) and in need of prioritized surveillance colonoscopy.

Methods: This was a prospective study conducted in the tertiary care setting. Participants completed a 2-sample FIT (OC-Sensor, Eiken Chemical Company) within 90 days of surveillance colonoscopy. The sensitivity of FIT for detection of AN (CRC or advanced adenoma) in moderate- and high-risk individuals was determined at fecal hemoglobin thresholds between 2 and 80 μg/g feces.

Results: A total of 766 patients were included (median age, 66.1 years [interquartile range, 58.1-72.9]; 49.9% male), with AN detected in 8.6% (66/766, including 5 CRC). For moderate-risk individuals (with prior history of adenoma or a significant family history of CRC), sensitivity of FIT for AN ranged from 73.5% at 2 μg/g feces, to 10.2% at 80 μg/g feces. For high-risk conditions (confirmed/suspected genetic syndromes or prior CRC), sensitivity of FIT was similar, ranging from 70.6% at the lowest positivity threshold of 2 μg/g feces, to 11.8% at 80 μg/g feces. Independent variables in the whole cohort for association with detection of AN at surveillance colonoscopy were age (odds ratio, 1.03; 95% confidence interval, 1.00-1.06) and FIT hemoglobin result ≥10 μg/g feces (odds ratio, 1.81; 95% confidence interval, 1.04-3.16).

Conclusions: The use of FIT before surveillance colonoscopy provides clinicians with insights into the risk of AN. This raises the possibility of a method to triage individuals, facilitating the more efficient management of endoscopic resources.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cgh.2023.09.016DOI Listing

Publication Analysis

Top Keywords

μg/g feces
20
surveillance colonoscopy
16
sensitivity fit
12
fecal immunochemical
8
advanced neoplasia
8
crc sensitivity
8
odds ratio
8
95% confidence
8
confidence interval
8
fit
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!