Diagnostic Accuracy and Safety Between two Needle Sizes in Percutaneous Trans-Thoracic Biopsy for the Evaluation of Pulmonary Lesions.

J Nepal Health Res Counc

Department of Radiology, Intervention Radiology section, Chitwan Medical College, Bharatput-10, Tribhuvan University, Nepal.

Published: September 2023

Background: Percutaneous trans-thoracic lung biopsy has a crucial role in diagnosing lung lesions including lung cancer. However, there is no clear guideline regarding the needle size in percutaneous trans-thoracic lung biopsy. This study aims to evaluate the diagnostic accuracy and complication rate between two needle sizes for percutaneous trans-thoracic lung biopsy.

Methods: A retrospective review of patients with lung lesions who underwent percutaneous trans-thoracic lung biopsy between November 2010 and December 2019 was performed. The demographic data, imaging finding, biopsy technique, complication and histologic outcome were recorded and analyzed. Propensity score matching was done to reduce bias in baseline characteristics.

Results: Of 377 patients who underwent percutaneous trans-thoracic lung biopsy, 331 patients had complete information. The patients were divided in two groups, comprising of 153 patients in 18G needle group and 178 patients in 20G needle group. After propensity score matching, there were 126 patients left in each group. The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value for 18G needle group were 92.9%, 98.1%, 65.0%, 93.7% and 86.7%, respectively. For 20G needle group, the diagnostic accuracy, sensitivity, specificity, predictive value and negative predictive value were 96.0%, 99.0%, 83.3%, 96.2% and 95.2%, respectively. The immediate complication rate was 35.7% and 31.7% in 18G and 20 G needle groups (p= 0.505), respectively.

Conclusions: There was no difference in diagnostic accuracy and immediate complication rates between 18G and 20G needle use for percutaneous trans-thoracic lung biopsy.

Download full-text PDF

Source
http://dx.doi.org/10.33314/jnhrc.v21i1.4598DOI Listing

Publication Analysis

Top Keywords

percutaneous trans-thoracic
28
trans-thoracic lung
24
diagnostic accuracy
20
lung biopsy
20
needle group
16
18g needle
12
20g needle
12
needle
9
lung
9
needle sizes
8

Similar Publications

The effect of concurrent acetylsalicylic acid on hemorrhagic complications during percutaneous image-guided lung biopsy.

Respir Med Res

December 2024

Department of Thoracic Oncology, Pleural Diseases and Interventional Pulmonology, Marseille, France.

Background: CT-guided trans-thoracic lung biopsy (CT-TTLB) is efficient and widely used to diagnose pulmonary nodules. After pneumothorax, the second most frequent complication is hemoptysis, which can be life-threatening. These patients often have comorbidities and are on acetylsalicylic-acid (ASA) therapy.

View Article and Find Full Text PDF

Aims: Suture-mediated patent fossa ovalis (PFO) closure is a recent technique, achieving closure by means of a simple suture. The differences between traditional occluders and suture might have different impacts on atrial function. The aim of this study was to evaluate atrial function after PFO closure by direct suture and traditional occluders.

View Article and Find Full Text PDF

Pediatric lung abscess is a rare and poorly studied disease entity. In the past, prolonged courses of intravenous (IV) antibiotics have been successfully used; however, with the advent of interventional radiology, the main therapeutic approach is through percutaneous placement of pigtail catheters with ultrasound and computed tomography (CT) direction, where available. The pathogen yield identified from fluid samples of the abscess has dramatically increased owing to the greater invasive measures, such as aspiration and drainage, as well as enhanced microbiological diagnostic methods, which also include polymerase chain reaction testing.

View Article and Find Full Text PDF

Bicuspidisation of unicuspid stenotic pulmonary valve in a nine-year-old male.

Cardiol Young

May 2024

Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint-Luc, Université catholique de Louvain, Brussels, Belgium.

We report the case of a 9-year-old male with severe congenital pulmonary valve stenosis referred to our centre for percutaneous valvotomy. On admission, trans-thoracic echocardiogram confirmed a unicuspid pulmonary valve with a peak/mean pulmonary valve gradient of 91/53 mmHg and a pulmonary annulus of 13.8 mm (-0.

View Article and Find Full Text PDF

Diagnostic Accuracy and Safety Between two Needle Sizes in Percutaneous Trans-Thoracic Biopsy for the Evaluation of Pulmonary Lesions.

J Nepal Health Res Counc

September 2023

Department of Radiology, Intervention Radiology section, Chitwan Medical College, Bharatput-10, Tribhuvan University, Nepal.

Background: Percutaneous trans-thoracic lung biopsy has a crucial role in diagnosing lung lesions including lung cancer. However, there is no clear guideline regarding the needle size in percutaneous trans-thoracic lung biopsy. This study aims to evaluate the diagnostic accuracy and complication rate between two needle sizes for percutaneous trans-thoracic lung biopsy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!