Purpose: The current study was conducted to investigate the electrocardiographic (ECG) characteristics of idiopathic premature ventricular contractions (PVCs) originating from the aortic sinus cusp (ASC) and establish a novel ECG criterion to discriminate PVCs originating from the right coronary cusp (RCC), left coronary cusp (LCC), and the left and right coronary cusp junction (LRJ).

Methods: A retrospective analysis was performed on a total of 133 patients with idiopathic PVCs who underwent successful mapping and ablation. The sites of origin (SOO) were confirmed using fluoroscopy and a three-dimensional mapping system during radiofrequency catheter ablation (RFCA). Among the patients, 69 had PVCs originating from the LCC, 39 from the RCC, and 25 from the LRJ. Characteristics of surface 12‑lead electrocardiograms (ECGs) recorded during PVCs were analyzed. Q-, R-, S, and R'-wave amplitudes were measured in lead I, and the lead I R-wave indexes (IRa, IRb, IRc, IRd, and IRe) were derived by employing multiplication, subtraction, sum, and division operations on these ECG measurements. Notably, IRb and IRe demonstrated usefulness as ECG indexes for discriminating PVCs originating from RCC, LCC, and LRJ in the ASC.

Results: The R- and S-wave amplitudes in lead I exhibited statistically significant differences among the three groups (P < 0.001 and P < 0.001, respectively). In discriminating PVCs originating from the RCC from the other two groups, IRb showed the largest area under the curve (AUC) of 0.813, as assessed by receiver operating characteristic (ROC) analysis, with a cutoff value of ≤0.5 indicating PVCs of RCC origin. The sensitivity and specificity were 80.3% and 78.7%, respectively. For discriminating PVCs arising from the LCC from those in the LRJ group, IRe exhibited the largest AUC of 0.801, with an optimal cutoff value of 0. An IRe value >0 indicated PVCs originating from the LRJ, while an IRe value ≤0 indicated PVCs originating from the LCC. The sensitivity and specificity of the IRe index were 84.0% and 70.7%, respectively.

Conclusion: Lead I R-wave indexes provided simple and useful ECG criteria for discriminating PVCs originating from the LCC, RCC, and LRJ in the left ventricular outflow tract (LVOT).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jelectrocard.2023.09.005DOI Listing

Publication Analysis

Top Keywords

pvcs originating
16
coronary cusp
12
lead r-wave
8
r-wave indexes
8
idiopathic premature
8
premature ventricular
8
ventricular contractions
8
aortic sinus
8
left coronary
8
pvcs
6

Similar Publications

Determining the QRS axis: visual estimation is equal to calculation.

Herzschrittmacherther Elektrophysiol

January 2025

Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625, Hannover, Germany.

Background: The QRS axis of the electrocardiogram (ECG) is often considered in clinical practice, but its determination is frequently limited to a rough estimation, such as "normal", with left or right deviation, and superior or inferior in the case of premature ventricular complexes (PVCs). However, a more exact determination of the QRS axis may be warranted in certain scenarios, such as to determine the origin of PVCs more precisely, and is attainable by visual estimation using the hexaxial reference system.

Objectives: The aim of this study was to determine how well such an estimation of the QRS axis would correlate with the axis calculated by formulas.

View Article and Find Full Text PDF

Premature ventricular contractions (PVCs) are a common finding in patients with surgically repaired congenital heart defects including transposition of the great arteries (D-TGA). While often asymptomatic, PVCs can sometimes lead to palpitations, dyspnea, and hemodynamic compromise, requiring therapeutic intervention. The arterial switch operation is the preferred treatment for D-TGA, but these patients have a 2% incidence of ventricular arrhythmias and 1% incidence of sudden cardiac death post-operatively.

View Article and Find Full Text PDF

Background: Predicting premature ventricular contraction (PVC) origin pre-ablation is a fundamental step, as right ventricular outflow tract (RVOT) PVC often leads to higher success rates.

Objective: To compare nine published ECG criteria to differentiate between RVOT and non-RVOT origins of PVCs and develop a stepwise algorithm using those criteria to better determine PVC origin to predict ablation success.

Methods: Two centers were involved in this study, the derivation group and the validation group.

View Article and Find Full Text PDF

Background: The Apple Watch (AW) can record single-lead electrocardiograms (ECGs) and has been investigated for arrhythmia detection. In this study we evaluated its accuracy in identifying the origin of premature ventricular contractions (PVCs) vs. standard 12-lead ECGs.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate a specific ECG measurement—the 'time to first nadir of the QRS complex in aVR compared to aVL'—to differentiate between left and right outflow tract premature ventricular complexes (PVCs) in patients.
  • Data was collected from 88 patients who underwent ablation for outflow tract PVCs, finding that 57.9% had PVCs originating from the left ventricular outflow tract (LVOT) and 42.1% from the right ventricular outflow tract (RVOT).
  • The findings suggest that while this new measurement isn't as precise as existing ECG criteria, it can still assist in determining the origin of PVCs, with certain ratios indicating a higher likelihood of RVOT
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!