Purpose: The current study was conducted to investigate the electrocardiographic (ECG) characteristics of idiopathic premature ventricular contractions (PVCs) originating from the aortic sinus cusp (ASC) and establish a novel ECG criterion to discriminate PVCs originating from the right coronary cusp (RCC), left coronary cusp (LCC), and the left and right coronary cusp junction (LRJ).
Methods: A retrospective analysis was performed on a total of 133 patients with idiopathic PVCs who underwent successful mapping and ablation. The sites of origin (SOO) were confirmed using fluoroscopy and a three-dimensional mapping system during radiofrequency catheter ablation (RFCA). Among the patients, 69 had PVCs originating from the LCC, 39 from the RCC, and 25 from the LRJ. Characteristics of surface 12‑lead electrocardiograms (ECGs) recorded during PVCs were analyzed. Q-, R-, S, and R'-wave amplitudes were measured in lead I, and the lead I R-wave indexes (IRa, IRb, IRc, IRd, and IRe) were derived by employing multiplication, subtraction, sum, and division operations on these ECG measurements. Notably, IRb and IRe demonstrated usefulness as ECG indexes for discriminating PVCs originating from RCC, LCC, and LRJ in the ASC.
Results: The R- and S-wave amplitudes in lead I exhibited statistically significant differences among the three groups (P < 0.001 and P < 0.001, respectively). In discriminating PVCs originating from the RCC from the other two groups, IRb showed the largest area under the curve (AUC) of 0.813, as assessed by receiver operating characteristic (ROC) analysis, with a cutoff value of ≤0.5 indicating PVCs of RCC origin. The sensitivity and specificity were 80.3% and 78.7%, respectively. For discriminating PVCs arising from the LCC from those in the LRJ group, IRe exhibited the largest AUC of 0.801, with an optimal cutoff value of 0. An IRe value >0 indicated PVCs originating from the LRJ, while an IRe value ≤0 indicated PVCs originating from the LCC. The sensitivity and specificity of the IRe index were 84.0% and 70.7%, respectively.
Conclusion: Lead I R-wave indexes provided simple and useful ECG criteria for discriminating PVCs originating from the LCC, RCC, and LRJ in the left ventricular outflow tract (LVOT).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelectrocard.2023.09.005 | DOI Listing |
Herzschrittmacherther Elektrophysiol
January 2025
Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625, Hannover, Germany.
Background: The QRS axis of the electrocardiogram (ECG) is often considered in clinical practice, but its determination is frequently limited to a rough estimation, such as "normal", with left or right deviation, and superior or inferior in the case of premature ventricular complexes (PVCs). However, a more exact determination of the QRS axis may be warranted in certain scenarios, such as to determine the origin of PVCs more precisely, and is attainable by visual estimation using the hexaxial reference system.
Objectives: The aim of this study was to determine how well such an estimation of the QRS axis would correlate with the axis calculated by formulas.
BMC Cardiovasc Disord
December 2024
Magdi Yacoub Heart Foundation, Cairo, Egypt.
Premature ventricular contractions (PVCs) are a common finding in patients with surgically repaired congenital heart defects including transposition of the great arteries (D-TGA). While often asymptomatic, PVCs can sometimes lead to palpitations, dyspnea, and hemodynamic compromise, requiring therapeutic intervention. The arterial switch operation is the preferred treatment for D-TGA, but these patients have a 2% incidence of ventricular arrhythmias and 1% incidence of sudden cardiac death post-operatively.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Heart Rhythm Center, Division of Cardiology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.
Background: Predicting premature ventricular contraction (PVC) origin pre-ablation is a fundamental step, as right ventricular outflow tract (RVOT) PVC often leads to higher success rates.
Objective: To compare nine published ECG criteria to differentiate between RVOT and non-RVOT origins of PVCs and develop a stepwise algorithm using those criteria to better determine PVC origin to predict ablation success.
Methods: Two centers were involved in this study, the derivation group and the validation group.
Circ J
January 2025
Department of Cardiovascular Medicine, Endocrinology and Metabolism, Faculty of Medicine, Tottori University.
Background: The Apple Watch (AW) can record single-lead electrocardiograms (ECGs) and has been investigated for arrhythmia detection. In this study we evaluated its accuracy in identifying the origin of premature ventricular contractions (PVCs) vs. standard 12-lead ECGs.
View Article and Find Full Text PDFJ Electrocardiol
January 2025
Prof. Marmara University School of Medicine, Department of Cardiology, Istanbul, Turkey.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!