A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A scalogram tensor decomposition based ECG quality assessment. | LitMetric

ECG quality assessment is crucial for reducing false alarms and physician strain in automated diagnosis of cardiovascular diseases. Recent researches have focused on constructing an automatic noisy ECG record rejection mechanism. This work develops a noisy ECG record rejection system using scalogram and Tucker tensor decomposition. The system can reject ECG records, which cannot be analyzed or diagnosed. Scalogram of all 12‑lead ECG signals per subject are stacked to form a 3-way tensor. Tucker tensor decomposition is applied with empirical settings to obtain the core tensor. The core tensor is reshaped to form the latent features set. When tested using the PhysioNet challenge 2011 dataset in five-fold cross validation settings, the RusBoost ensemble classifier proved to be a very reliable option, producing an accuracy of 92.4% along with sensitivity of 87.1% and specificity of 93.5%. According to the experimental findings, combining the scalogram with Tucker tensor decomposition yields competitive performance and has the potential to be used in actual evaluation of ECG quality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jelectrocard.2023.09.002DOI Listing

Publication Analysis

Top Keywords

tensor decomposition
16
ecg quality
12
tucker tensor
12
quality assessment
8
noisy ecg
8
ecg record
8
record rejection
8
scalogram tucker
8
core tensor
8
ecg
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!