AI Article Synopsis

  • The DMEK procedure for corneal transplantation is difficult because unscrolling the donor graft in the eye can harm the graft's viability and integration, especially when the graft is young.
  • Researchers propose that the tight scrolling of grafts is caused by a concentration gradient in the preserving medium, leading to folding of the graft tissue.
  • Experimental models using chitosan bilayers show that engineering the graft's preserving medium can lessen scroll tightness, which may improve surgical outcomes and recovery.

Article Abstract

The Descemet Membrane Endothelial Keratoplasty (DMEK) procedure for corneal transplantation is challenging due to the need to unscroll the donor graft within the recipient's eye. This process of unscrolling is complex, time-consuming, leads to a loss of endothelial cells and, most importantly, can negatively impact the graft's adhesion and integration with the host tissue after surgery. This problem is particularly evident when the graft is young. However, the physics behind this scrolling is not well understood, and therefore no sustainable solution is attained. Here, we propose that the concentration gradient of the medium used during transplant leads to a displacement gradient across the graft thickness, resulting in an out-of-plane folding or scrolling of the graft tissue. Using chitosan bilayer-based experimental models, it is experimentally demonstrated that this diffusion-coupled-deformation phenomenon can successfully explain why younger donor grafts tend to scroll tighter than older ones. Most importantly, we illustrate here through experiments that the medium can be engineered to reduce the scroll tightness and thus reduce the surgical inconveniences and improve post-transplant recovery. STATEMENT OF SIGNIFICANCE: This paper addresses a major issue that surgeons face while doing Descemet Membrane Endothelial Keratoplasty (DMEK) in unscrolling grafts during the graft insertion procedure. The currently used tapping method to unscroll the graft inside the patient's eye significantly reduces endothelial cell count, thus affecting its lifetime. Surprisingly, the physics behind graft scrolling is not well understood, so no sustainable solutions are proposed by the medical community. In this work, we present the underlying mechanism of DMEK graft scroll and illustrate experimentally the reason for scroll tightness through a chitosan bilayer based experiment model. Most importantly, we have successfully demonstrated that the preserving medium of the grafts can be engineered to reduce scroll tightness.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actbio.2023.09.024DOI Listing

Publication Analysis

Top Keywords

descemet membrane
12
membrane endothelial
12
endothelial keratoplasty
12
scroll tightness
12
keratoplasty dmek
8
graft
8
scrolling well
8
well understood
8
understood sustainable
8
engineered reduce
8

Similar Publications

Purpose: Anterior segment optical coherence tomography (AS-OCT) is increasingly being used to complement slit-lamp biomicroscopy in the evaluation of corneal infections. Our purpose was to analyze, compare, and correlate the clinical signs elicited by these 2 methods in patients with infectious keratitis (IK).

Methods: Slit-lamp photomicrographs (diffuse and slit beam) and AS-OCT scans were obtained from 20 consecutive patients (21 eyes) with IK.

View Article and Find Full Text PDF

Descemet's membrane (DM) detachment is a significant, if rare, risk of intracameral injection of viscoelastic to treat hypotony after glaucoma filtration surgery. We describe two cases of DM detachment following inadvertent injection of viscoelastic into the posterior stroma and the techniques used for their repair. In both cases, conventional air tamponade failed to resolve the detachment, and further surgical intervention was required.

View Article and Find Full Text PDF

Purpose: To describe a technique involving combined endothelialectomy and trypan blue staining to allow for improved visualization and Descemet membrane (DM) removal during endothelial keratoplasty.

Methods: Endothelialectomy with 2 disposable endothelial irrigating cannulas (Vortex and Sterimedix) and an irrigation-aspiration handpiece are described. Several passes over the desired area are made to ensure adequate endothelialectomy treatment.

View Article and Find Full Text PDF

Fuchs Endothelial Corneal Dystrophy (FECD) is the most frequent indication for corneal transplantation, with Descemet membrane endothelial keratoplasty (DMEK), Descemet stripping automated endothelial keratoplasty (DSAEK), and penetrating keratoplasty (PK) being viable options. This retrospective study compared 10-year outcomes of these techniques in a large cohort of 2956 first-time keratoplasty eyes treated for FECD at a high-volume corneal transplant center in Germany. While DMEK and DSAEK provided faster visual recovery (median time to BSCVA ≥ 6/12 Snellen: DMEK 7.

View Article and Find Full Text PDF

Purpose: To evaluate Descemet membrane endothelial keratoplasty (DMEK) for failed endothelial keratoplasty (EK).

Methods: We reviewed 362 consecutive DMEK cases for failed EK (Descemet stripping endothelial keratoplasty (DSEK) or DMEK), 118 for early EK failure, and 244 for late failure in 333 eyes of 323 patients without penetrating keratoplasty. Rejection and graft survival rates were assessed with Kaplan-Meier analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!