Invasive physiologic assessment of coronary artery stenosis by resting full-cycle ratio and fractional flow reserve: a prospective observational study.

Sci Rep

Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine and Cardiovascular Center, Yongin Severance Hospital, Yongin, South Korea.

Published: September 2023

Resting full-cycle ratio (RFR), an alternative to fractional flow reserve (FFR) for evaluating intermediate coronary artery stenosis, helps reduce patients' time, cost, and discomfort. However, the validation data for RFR and FFR are lacking. We aimed to assess the diagnostic accuracy of RFR and FFR and evaluate effective decision-making for revascularization using their values. Patients subjected to an invasive physiological study for intermediate coronary artery stenosis in Yongin Severance hospital between October 2020 and April 2022 were prospectively and consecutively recruited. We evaluated the correlation between RFR and FFR measurements and the diagnostic performance of RFR (≤ 0.89) versus FFR (≤ 0.80). In all, 474 intermediate coronary stenosis lesions from 400 patients were evaluated using RFR and FFR values. There was a strong linear relationship between RFR and FFR (r = 0.75, 95% CI 0.70-0.78, p < 0.01). Comparing diagnostic performance between RFR and FFR, RFR demonstrated diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 85.0%, 80.0%, 86.7%, 67.1%, and 92.7%, respectively. We analyzed the RFR value in the hyperemia zone (0.86-0.93) according to positive (RFR: 0.86-0.89) and negative (RFR: 0.90-0.93) areas. PPV in positive area is 47.8% (95% Confidence Interval [CI]: 33.8% to 62.0%) and NPV in negative area is 87.7% (95% CI: 80.3% to 93.1%). Excellent correlation exists between RFR and FFR and the diagnostic value of RFR without hyperemia compared with FFR in establishing the accurate functional significance of coronary artery stenosis was shown. RFR alone could evaluate the functional significance of coronary artery stenosis without unnecessary hyperemia, except in the positive area.Trial registration: URL: http://trialsearch.who.int ; Unique identifier: KCT0005255.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10516888PMC
http://dx.doi.org/10.1038/s41598-023-43082-1DOI Listing

Publication Analysis

Top Keywords

rfr ffr
20
coronary artery
12
artery stenosis
12
intermediate coronary
12
resting full-cycle
8
full-cycle ratio
8
fractional flow
8
flow reserve
8
rfr
7
ffr
7

Similar Publications

Article Synopsis
  • The study investigates how well the drop in coronary pressure after administering nitroglycerin (NTG) can predict fractional flow reserve (FFR) compared to the resting full-cycle ratio (RFR).
  • In total, 202 vessels were analyzed from two prospective studies, where NTG-Pd/Pa showed a strong correlation with FFR (r = 0.945) and a cutoff value of 0.85 was established.
  • Results indicated that NTG-Pd/Pa performed better than RFR in predicting FFR ≤ 0.8, with higher accuracy (91% vs. 84%) and sensitivity, making it a potentially more effective diagnostic tool.
View Article and Find Full Text PDF

Impact of Kidney Function on Physiological Assessment of Coronary Circulation.

Rev Cardiovasc Med

October 2024

Clinical Department of Cardiology and Cardiovascular Interventions, University Hospital, 30-688 Krakow, Poland.

Background: Diagnosing myocardial ischemia in chronic kidney disease (CKD) patients is crucial since coronary artery disease (CAD) forms the predominant cause of mortality in these patients. Thus, this study aimed to assess the impact of kidney function on the results of coronary circulation physiological assessment.

Methods: Data were collected from 279 consecutive patients admitted to the Clinical Department of Cardiology and Cardiovascular Interventions at the University Hospital in Krakow.

View Article and Find Full Text PDF

Coronary Physiological Indexes to Evaluate Myocardial Ischemia in Patients With Aortic Stenosis Undergoing Valve Replacement.

JACC Cardiovasc Interv

October 2024

Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium; Department of Cardiovascular Medicine, University Hospitals Leuven, Leuven Belgium.

Background: The evaluation of myocardial ischemia in patients with aortic valve stenosis (AS) with concomitant coronary artery disease (CAD) and possible microvascular dysfunction (MVD) is challenging because fractional flow reserve (FFR) and the resting full-cycle ratio (RFR) have not been validated in this clinical setting.

Objectives: The objectives of this study in patients with AS and CAD were: 1) to describe the relationship between hyperemic and resting indexes; 2) to investigate the acute and long-term effects of aortic valve replacement (AVR) on epicardial indexes and microvascular function; 3) to assess the impact of these changes on clinical decision making; and 4) to determine FFR/RFR ischemia cutoff points in AS.

Methods: In this prospective multicentric study, we performed serial measurements of FFR and RFR and evaluated MVD by means of coronary flow reserve, the index of microvascular resistance, and microvascular resistance reserve in patients with severe AS and intermediate to severe CAD before and 6 months after AVR.

View Article and Find Full Text PDF
Article Synopsis
  • - The study investigates the relationship between hyperemic (FFR) and non-hyperemic indexes (NHi) of coronary stenosis, highlighting a 20% discordance in their results and aiming to develop a formula to understand this discrepancy.
  • - A total of 51 patients were analyzed, with findings showing strong correlations between the measured and estimated data, revealing factors that affect discordance based on microvascular resistance and stenosis resistance.
  • - The conclusion notes that the reliability of various combinations of FFR and NHi can change depending on specific conditions, suggesting that different combinations are more accurate under different scenarios of microvascular and stenosis resistance.
View Article and Find Full Text PDF

The effect of hydrostatic pressure on invasive coronary pressure measurements: Comparison with [O]HO-positron emission tomography flow data.

Catheter Cardiovasc Interv

November 2024

Department of Cardiology, Amsterdam Cardiovascular Sciences Amsterdam University Medical Centers, Vrije Universiteit, Amsterdam, The Netherlands.

Background: Fractional flow reserve (FFR) has emerged as the invasive gold standard for assessing vessel-specific ischemia. However, FFR measurements are influenced by the hydrostatic effect, which might adversely impact the assessment of ischemia.

Aims: This study aimed to investigate the impact of hydrostatic pressure on FFR measurements by correcting for the height and comparing FFR with [O]HO positron emission tomography (PET)-derived relative flow reserve (RFR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!