Detecting gravitationally lensed supernovae is among the biggest challenges in astronomy. It involves a combination of two very rare phenomena: catching the transient signal of a stellar explosion in a distant galaxy and observing it through a nearly perfectly aligned foreground galaxy that deflects light towards the observer. Here we describe how high-cadence optical observations with the Zwicky Transient Facility, with its unparalleled large field of view, led to the detection of a multiply imaged type Ia supernova, SN Zwicky, also known as SN 2022qmx. Magnified nearly 25-fold, the system was found thanks to the standard candle nature of type Ia supernovae. High-spatial-resolution imaging with the Keck telescope resolved four images of the supernova with very small angular separation, corresponding to an Einstein radius of only = 0.167″ and almost identical arrival times. The small and faintness of the lensing galaxy are very unusual, highlighting the importance of supernovae to fully characterize the properties of galaxy-scale gravitational lenses, including the impact of galaxy substructures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10509034 | PMC |
http://dx.doi.org/10.1038/s41550-023-01981-3 | DOI Listing |
Int J Surg Case Rep
December 2024
Department of Orthopedics, Jigme Dorji Wangchuck National Referral Hospital, Thimphu, Bhutan. Electronic address:
Introduction: Melorheostosis is extremely rare non-cancerous lesion of bone mainly affecting the long bones and soft tissues. The incidence is 0.9 per million population.
View Article and Find Full Text PDFAnn Med
December 2024
Division of Allergy, Immunology, and Pulmonary Medicine, Department of Pediatrics, Vanderbilt University Medical Center, Nashville, TN, USA.
Anal Chim Acta
November 2024
Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada. Electronic address:
In time-weighted averaging (TWA) with needle trap extraction (NTE), the control of the sampling rate is critical for accurate analysis. By adjusting the diffusion length and cross-sectional area, the sampling rate can be modified in accordance with Fick's first law of diffusion. In this study, deactivated fused silica tubing (DFST) of varying lengths was used to fine-tune these parameters, allowing for precise control of the sampling rate in TWA-NTE devices.
View Article and Find Full Text PDFOxf Med Case Reports
October 2024
Department of Radiology, Mohammed V Military Instruction Hospital, Faculty of Medicine and Pharmacy of Rabat, Mohamed V University, Rabat 91000, Morocco.
Melorheostosis is a rare benign bone dysplasia characterized by dysostosis and sclerosis. The classic "dripping candle wax" appearance on imaging is a typical finding for the diagnosis. The authors report the case of a patient presenting with a hard and painful mass on the dorsal side of the hand.
View Article and Find Full Text PDFWorld J Methodol
June 2024
Department of Endocrinology and Nutrition, Miguel Servet University Hospital, Zaragoza 50009, Spain.
Continuous glucose monitoring (CGM) is a popular technology among the diabetic population, especially in patients with type 1 diabetes and those with type 2 diabetes treated with insulin. The American Diabetes Association recommends standardization of CGM reports with visual cues, such as the ambulatory glucose profile. Nevertheless, interpreting this report requires training and time for CGM to be cost-efficient.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!