Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A precise, Eco-friendly, and highly sensitive RP-HPLC method was employed using quality-by-design principles to concurrently identify cephalexin and cefixime residues in the manufacturing machines using a hypersil BDS C18 column (250 × 4.6 mm, 5 μm) at wavelength 254 nm. The Box-Behnken design was applied to obtain the best chromatographic conditions with the fewest possible trials. Three independent factors viz organic composition, flow rate, and pH were used to assess their effects on the responses' resolution and retention time. Overlay plot and desirability functions were implemented to predict responses of the high resolution and relatively short retention time using a mobile phase composed of acidic water: acetonitrile (85:15, v/v) at pH 4.5 adjusted by phosphoric acid with a flow rate of 2.0 mL/min. The spectral overlapping of the drugs was successfully resolved by the mean centering ratio (MCR) spectra approach at 261 nm and 298 nm for cephalexin and cefixime, respectively. Good linearity results were obtained for the suggested HPLC and MCR methods over the concentration range of (0.05-10 ppm) and (5-30 ppm) with a detection limit of 0.003, 0.004, 0.26, and 0.23 ppm, and quantitation limits of 0.008, 0.013, 0.79, and 0.68 ppm for cephalexin and cefixime, respectively, with a correlation coefficient of ≥ 0.9998 and good swab recovery results of 99-99.5%. A process capability index was accomplished for chemical and micro results, illustrating that both are extremely capable. The suggested method was effectively validated using ICH recommendations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10514345 | PMC |
http://dx.doi.org/10.1038/s41598-023-40010-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!