Download full-text PDF

Source
http://dx.doi.org/10.1136/jme-2023-109441DOI Listing

Publication Analysis

Top Keywords

downgrades potential
4
potential source
4
source moral
4
moral tension
4
downgrades
1
source
1
moral
1
tension
1

Similar Publications

The mechanism and severity of mitral valve (MV) regurgitation (MR) play a critical role in guiding treatment decisions. Transthoracic echocardiography (TTE) is the primary diagnostic modality for evaluating MV disease. Discordant findings on TTE can be further quantified through transesophageal echocardiography (TEE).

View Article and Find Full Text PDF

Aim: To assess recent colonoscopies and CT scans in conjunction with the feacal immunochemical test (FIT) for possibly downgrading urgent suspected cancer (USC) referrals.

Methods:  A retrospective single-centre study was conducted, including all USC referrals for colonoscopy in 2022, excluding anal cancers. The CT and colonoscopy findings for a two-year period prior to the referral, along with the FIT result (if done), were noted.

View Article and Find Full Text PDF

Background: Drug resistance remains a significant obstacle to Acute myeloid leukemia (AML) successful treatment, often leading to therapeutic failure. Our previous studies demonstrated that Glioma-associated oncogene-1 (GLI1) reduces chemotherapy sensitivity and promotes cell proliferation in AML cells. GANT61, an inhibitor of GLI1, emerges as a promising candidate in AML treatment.

View Article and Find Full Text PDF
Article Synopsis
  • Using MRI-fusion guided prostate biopsy (PB) leads to better agreement with prostatectomy histopathology results compared to traditional 12-core TRUS biopsy, especially in patients with higher-risk prostate cancer.
  • In a study involving 218 men diagnosed with prostate cancer, those who underwent MRI-fusion PB had a significantly higher concordance rate (73.1% vs. 42.9%) with the final pathology from surgery.
  • The research highlighted that the number of cancer-involved regions in the prostate is an important factor influencing concordance, indicating that MRI-fusion techniques enhance diagnostic accuracy and treatment planning for patients.
View Article and Find Full Text PDF

Self-Poled Bismuth Ferrite Thin Film Micromachined for Piezoelectric Ultrasound Transducers.

Adv Mater

December 2024

Institute for Superconducting and Electronic Materials, Faculty of Engineering and Information Sciences, University of Wollongong, Innovation Campus, North Wollongong, NSW, 2500, Australia.

Piezoelectric micromachined ultrasound transducers (pMUTs), especially those using lead-free materials, are crucial next-generation microdevices for precise actuation and sensing, driving advancements in medical, industrial, and environmental applications. Bismuth ferrite (BiFeO) is emerging as a promising lead-free piezoelectric material to replace Pb(Zr,Ti)O in pMUTs. Despite its potential, the integration of BiFeO thin films into pMUTs has been hindered by poling issues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!