Case: An 81-year-old man with a history of left medial unicompartmental knee arthroplasty (mUKA) 8 years prior presented to the outpatient clinic with gradually increasing medial left knee pain of 6 years of duration. He underwent left conversion robotic-assisted total knee arthroplasty (RA TKA). At 1-year follow-up, the patient reported satisfactory clinical outcomes and excellent component alignment on x-rays.

Conclusion: This case highlights using RA TKA for failed mUKA as a viable and promising conversion arthroplasty alternative technique that may improve surgical outcomes by enhancing implant alignment and positioning, protecting the soft tissues, and preserving bone stock.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.CC.23.00090DOI Listing

Publication Analysis

Top Keywords

knee arthroplasty
16
medial unicompartmental
8
unicompartmental knee
8
total knee
8
knee
5
arthroplasty
5
robotic-assisted conversion
4
conversion failed
4
failed medial
4
arthroplasty total
4

Similar Publications

Objective: This study aims to elucidate the impact of varying tourniquet application timings on postoperative pain and the bone cement interface following TKA.

Method: Patients who underwent TKA in our department between March 2021 and July 2023 were included in this study. They were randomly assigned to three groups: Group 1 used tourniquets throughout the operation, Group 2 applied tourniquets before the osteotomy, and Group 3 applied tourniquets after completing the osteotomy.

View Article and Find Full Text PDF

Background: Previous clinical studies suggest that preserving the anterior cruciate ligament (ACL) is crucial for stable knee motion and long-term longevity of the reconstructed knee. The ACL damage or loss often occurs in advanced medial osteoarthritis (OA). This study aimed to investigate the correlation between ACL damage and varus deformity progression as a risk factor for ACL tears in knee OA.

View Article and Find Full Text PDF

Background: Arthroplasty registries play a critical role in improving the quality of care and performing post-market surveillance of medical devices. We report the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) findings specific to the Biomet Vanguard XP bicruciate-retaining total knee implant.

Methods: Data were collected from MARCQI's 2019 report (February 15, 2012, through December 31, 2018).

View Article and Find Full Text PDF

Background: Robotic-assisted total knee arthroplasty (RA-TKA) was introduced to provide surgeons with virtual preoperative planning and intraoperative information to achieve the desired surgical goals in an effort to improve patient outcomes. The purpose of this study was to compare clinical outcomes and patient-reported outcome measures following primary TKA using RA-TKA vs manual instrumentation.

Methods: This was a retrospective cohort review study comparing 393 primary RA-TKAs vs 312 manual TKAs at a minimum 2-year follow-up.

View Article and Find Full Text PDF

Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure.