Optimal post height and diameter in preformed zirconia crown restoration on 3D-printed primary incisors.

J Clin Pediatr Dent

Department of Pediatric Dentistry, School of Dentistry, Kyungpook National University, 41940 Daegu, Republic of Korea.

Published: September 2023

In this study, fracture resistance was evaluated according to the post-diameter and -length in zirconia crown restorations on three-dimensional printed primary incisors undergone pulpectomy. One hundred-and-sixty primary incisor abutments were used which were artificially fabricated through 3D-printing. Each group was divided into two subgroups based on the zirconia post-diameter (1.5 mm and 2.0 mm) employed for post setting after pulpectomy. Furthermore, each group was divided into four subgroups based on the zirconia post-height (3.0, 4.0, 5.0 and 6.0 mm). Zirconia post setting was made by applying flowable resin after filling the pulp cavity with calcium hydroxide up to 3.0 mm below cemento-enamel junction (CEJ). Finally, a preformed zirconia crown of size #1 was cemented to the abutment through resin cement. A compressive load was applied to the middle palatal surface of incisors restored with zirconia crowns by using a universal testing machine at 145° angle which is the normal interincisal angle of children. The root fracture specimens were excluded and the samples fractured within crown and core parts were included in the final fracture resistance analysis. The group with 1.5-mm post-diameter and 5.0-mm post-height had the highest fracture resistance strength (130.63 ± 55.75 N) under masticatory pressure condition. Fracture resistance was statistically greater in 5.0-mm than in 4.0-mm and 3.0-mm post-height groups for 1.5-mm post-diameter subgroup. Moreover, 5.0-mm post-height subgroup had a statistically greater fracture resistance than that of 3.0-mm post-height subgroup for 2.0-mm post-diameter group. The 2.0-mm post-diameter subgroup had a statistically greater fracture resistance than that of 1.5-mm post-diameter subgroup for 3.0-mm and 4.0-mm post-heights. If zirconia post incorporation is required for deciduous incisor restoration, a post-length equal to facial CEJ level is recommended for gaining additional retention against masticatory pressure.

Download full-text PDF

Source
http://dx.doi.org/10.22514/jocpd.2023.053DOI Listing

Publication Analysis

Top Keywords

fracture resistance
24
zirconia crown
12
15-mm post-diameter
12
statistically greater
12
post-diameter subgroup
12
zirconia
8
preformed zirconia
8
primary incisors
8
group divided
8
divided subgroups
8

Similar Publications

Background/purpose: It remains unclear how the thickness and number of pulp-chamber lateral walls (PCLWs) affects fracture resistance in endocrown-restored teeth.

Materials And Methods: 64 mandibular molars were collected and randomly divided into eight groups (n = 8). In group C (control group), the teeth were untreated.

View Article and Find Full Text PDF

Chryseobacterium indologenes is a rare human pathogen which is nowadays considered an emerging fearsome organism because of its upcoming antibiotic resistance. We present a quite unique case of a multi drug resistant C. indologenes surgical wound infection in a patient submitted to cannulated screw fixation of a displaced medial malleolus fracture.

View Article and Find Full Text PDF

Developing hydrogels with high conductivity and toughness a facile strategy is important yet challenging. Herein, we proposed a new strategy to develop conductive hydrogels by growing metal dendrites. Water-soluble Sn ions were soaked into the gel and then converted to Sn dendrites an electrochemical reaction; the excessive Sn ions were finally removed by water dialysis, accompanied by dramatic shrinkage of the gel.

View Article and Find Full Text PDF

Light-Induced Transformation from Covalent to Supramolecular Polymer Networks.

ACS Macro Lett

January 2025

School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules, Shanghai Jiao Tong University, Shanghai 200240, P. R. China.

Stimuli-responsive polymers have demonstrated significant potential in the development of smart materials due to their capacity to undergo targeted property changes in response to external physical or chemical stimuli. However, the scales of response in most existing stimuli-responsive polymer systems are mainly focused on three levels: functional units, chain conformations, or polymer topologies. Herein, we have developed a covalent polymer network (CPN) capable of converting into a supramolecular polymer network (SPN) within bulk materials directly at the scale of polymer network types.

View Article and Find Full Text PDF

The main aim of the current study was to compare the effects of two strength training modalities (hypertrophy vs. contrast training) on bone health parameters, physical performance and quality of life in a group of subjects aged 60 and above with low skeletal muscle mass index (SMI). 45 older adults voluntarily participated in this study, but only 41 (22 women and 19 men) completed it.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!