Early detection and drug intervention with the appropriate timing and dosage are the main clinical challenges for ischemic stroke (IS) treatment. The conventional therapeutic agents relay fluorescent signals, which require real-time external light excitation, thereby leading to inevitable autofluorescence and poor tissue penetration. Herein, we report endogenous peroxynitrite (ONOO)-activated NPs that release NIR afterglow signals (λ 697 nm) for real-time monitoring of the progression of ischemia reperfusion (I/R) brain injury while releasing curcumin for the safe treatment of IS. The NPs exhibited bright NIR afterglow luminescence (maximum 732-fold increase), superb sensitivity (LOD = 82.67 nM), high energy-transfer efficiency (94.6%), deep tissue penetration (20 mm), outstanding antiapoptosis, and anti-inflammatory effects. The activated NIR afterglow signal obtained in mice with middle cerebral artery occlusion (MCAO) showed three functions: (i) the NPs are rapidly activated by endogenous ONOO, instantly illuminating the lesion area, distinguishing I/R damage from normal areas, which can be successfully used for endogenous ONOO detection in the early stage of IS; (ii) real-time reporting of generation and dynamic fluctuations of endogenous ONOO levels in the lesion area, which is of great value in monitoring the evolutionary mechanisms of IS; and (iii) dynamic monitoring of the release of curcumin drug for safe treatment. Indeed, the released curcumin effectively decreased apoptosis, enhanced survival, alleviated neuroinflammation, reduced brain tissue loss, and improved the cognition of MCAO stroke mice. This work is the first example of afterglow luminescence for early diagnosis, real-time reporting, drug tracing, and treatment for IS.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10561133 | PMC |
http://dx.doi.org/10.1021/acsami.3c08033 | DOI Listing |
Talanta
December 2024
The Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province and State Key Laboratory of Applied Organic Chemistry, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, PR China. Electronic address:
The key to the treatment of choroidal melanoma (CM) is to improve diagnostic efficiency and find a high-performance treatment to replace the traditional treatment of radiotherapy and enucleation. In this paper, for the first time, long afterglow luminescence material was applied to the integrated diagnosis and treatment of eyes, with its unique advantages in photoluminescence and afterglow luminescence to solve the bottleneck problem of real-time irradiation required for photothermal and photodynamic therapy (PTT and PDT). Based on the excellent photoluminescence and afterglow properties of ZnGaGeO:CrYbEr (ZGGO) nanoparticles, a nanoplatform ZGGO@Au@UiO-66@ZnPc:Dox-FA (GAUZD-FA) for NIR-Ⅱ imaging and triple-synergistic therapy (PTT, PDT and sustained-release drug) was constructed.
View Article and Find Full Text PDFChem Commun (Camb)
December 2024
Xiangya School of Pharmaceutical Sciences, Central South University Changsha, 410013, China.
Here we report an afterglow material, APT/TTQNPs. This material can be activated by superoxide anions (O˙) to emit NIR afterglow. APT/TTQNPs possess high selectivity, high sensitivity, and high imaging signal-to-noise ratio to O˙.
View Article and Find Full Text PDFACS Appl Bio Mater
December 2024
State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing 100029, People's Republic of China.
Afterglow fluorescence imaging has been extensively assessed in ultrasensitive bioimaging. Since it eliminates the need for real-time excitation light and thereby circumvents the autofluorescence background of tissue, it holds tremendous potential in accurate biomedical imaging. However, current afterglow probes are rare and emit light only in the visible to near-infrared (NIR) range, which is inadequate for imaging.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
School of Materials Science and Engineering, Liaocheng University, Liaocheng 252059, China. Electronic address:
Environmentally friendly natural polymer-based room temperature phosphorescence (RTP) materials exhibit promising applications in anti-counterfeiting and information encryption. However, the construction of natural polymer-based RTP materials with multicolor long afterglow and even persistent near-infrared (NIR) luminescence remains a tough challenge. Here, starch (S)-based ultralong RTP materials with wide color-tunability, persistent NIR luminescence are conveniently prepared through Förster resonance energy transfer (FRET) strategies.
View Article and Find Full Text PDFNano Lett
December 2024
School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444, China.
Afterglow luminescence has attracted increasing attention due to its prolonged emission, reduced autofluorescence, and minimized photodamage. However, persistent luminescence typically requires high-energy excitation (e.g.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!