A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Interlaminar endoscopic uniportal approach for implantation of a paddle lead larger than 10 mm for spinal cord stimulation: illustrative case. | LitMetric

Background: The authors aim to describe a new technique for implantation of a spinal cord stimulation paddle lead sized over 10 mm through an endoscopic uniportal approach. A new endoscopic cannula was developed for the passage of a paddle lead width between 10 and 13 mm. The distal portion of the cannula was designed with a larger opening, providing better visibility of the anterior portion of the adjacent structures, thus allowing a panoramic view of the electrode passage. An electrode was implanted in an 11-mm paddle.

Observations: After searching PubMed, Cochrane, and Lilacs databases, the authors found no mention of the implantation of a paddle electrode with a width greater than 10 mm. The implantation of a paddle electrode less than 10 mm wide is possible via endoscopic access using 10-mm working channels. However, for electrodes with a width greater than 10 mm, access via endoscopy is impossible, since the working channel is only 10 mm.

Lessons: The authors concluded that it is possible to pass electrodes safely and effectively with a paddle width between 10 and 13 mm using spinal endoscopy via uniportal interlaminar access. However, it is necessary to expand studies to elucidate this technique of endoscopic implantation of electrodes for neurostimulation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10555609PMC
http://dx.doi.org/10.3171/CASE23121DOI Listing

Publication Analysis

Top Keywords

implantation paddle
12
paddle lead
12
endoscopic uniportal
8
uniportal approach
8
spinal cord
8
cord stimulation
8
paddle electrode
8
width greater
8
paddle
6
implantation
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!