Evaluation of a point-of-care calcium device in bovine plasma and serum.

JDS Commun

Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman 99164-6610.

Published: September 2023

Hypocalcemia is a common metabolic disease in dairy cows, and it is defined as total calcium (tCa) blood concentration <2.0 mmol/L. The alternatives for the gold standard test to measure tCa in bovine blood are limited. Therefore, our objective was to compare the performance of the calcium (Ca) point-of-care compact analyzer (POC; ARKRAY Inc.) device with the gold standard method to measure bovine blood tCa concentration. Blood samples (n = 151) from dairy cows were collected within 24 h postpartum from multiparous and primiparous dairy cows for serum and plasma. Then, serum and plasma were stored at -80°C until further analyses with the gold standard method on an automatic analyzer (Cobas C501 analyzer; Roche Diagnostics) and the POC device. The tCa blood concentration was measured in the laboratory in plasma and serum samples using both methods within 10 mo of sample collection. Correlation coefficients (Spearman), coefficients of variation (CV, %), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, Passing and Bablok regression, and Bland-Altman agreement test were performed between the gold standard and the POC device. The range and median tCa plasma concentrations measured with the POC device were 1.1 to 2.8 mmol/L and 2.4 mmol/L, respectively. The range and median tCa serum concentrations measured with the POC device were 1.1 to 2.7 mmol/L and 2.3 mmol/L, respectively. The tCa blood concentrations range and median with the gold standard were 1.1 to 2.6 mmol/L and 2.3 mmol/L. The hypocalcemia prevalence of our study population was 11.2%. The CV were 1.89% and 0.55% for low and high tCa in plasma samples measured with the POC, respectively. The CV were 2.57% and 1.58% for low and high tCa in serum, respectively. The Spearman correlation coefficient showed a strong correlation between the gold standard and the POC device for both serum and plasma tCa concentration. The sensitivity of the POC device for both plasma (41.1%) and serum (64.7%) Ca was poor. However, the specificity of the POC device was perfect in plasma (99.2%) and serum (99.2%). The PPV in plasma and serum were 87.5% and 91.6%, respectively. Negative predicted values were 93.0% and 95.6% in plasma and serum. The mean (95% CI) difference between the gold standard and the POC device in plasma and serum were 0.35 (-0.52, 1.23) mmol/L and 0.19 (-0.53, 0.92) mmol/L, respectively. Finally, we observed a strong correlation between the POC device and the gold standard method for tCa plasma and serum. However, the clinical application of the POC device should be carefully considered because its ability to detect cows with hypocalcemia in serum or plasma samples was poor. However, the device performed better than previously analyzed POC devices and needs further improvement to be a valuable tool for the dairy industry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10505766PMC
http://dx.doi.org/10.3168/jdsc.2022-0346DOI Listing

Publication Analysis

Top Keywords

evaluation point-of-care
4
point-of-care calcium
4
calcium device
4
device bovine
4
bovine plasma
4
plasma serum
4
serum hypocalcemia
4
hypocalcemia common
4
common metabolic
4
metabolic disease
4

Similar Publications

Background: HIV-associated neurocognitive disorders (HAND) are prevalent complications of ageing with treated HIV, disproportionally affecting sub-Saharan Africa. Causal HAND treatments are lacking worldwide; therefore, reversible factors are important to explore. Sleep duration and quality are frequently associated with risk of cognitive impairments.

View Article and Find Full Text PDF

Background: Primary progressive aphasia (PPA) is a dementia syndrome characterized by language and communication impairments, with relative sparing of other cognitive domains. As a relatively rare dementia syndrome, there are few measures developed and validated for individuals with PPA. Development of outcome measures tailored to the communication experiences of persons with PPA (PwPPA) is critical for the accurate assessment of interventions success.

View Article and Find Full Text PDF

Background: Increasing calls for diversity in Alzheimer's disease and related dementias (ADRDesearch have fueled significant investments in recruitment personnel and activities. However, the essential work of identifying and authentically engaging communities of color in relationship-building begins well before, and continues long after, study recruitment activities take place. The purpose of this presentation is twofold: 1) to differentiate the work of trust-building and relationship cultivation from that of research study recruitment, and 2) to describe the necessary steps to ensure that relationship cultivation is ongoing and supported beyond the timeline of a singular research study.

View Article and Find Full Text PDF

Background: Measuring the effectiveness of dementia care programs is essential for ensuring quality care and aligning with value-based care principles, especially in practical, real-world clinical settings. A Delphi method, a consensus-building approach among experts, was used to identify practical metrics for evaluating dementia programs. The expert panel comprised a clinical psychologist, two healthcare executives, and a physician experienced in person-centered care for older adults in residential and facility settings.

View Article and Find Full Text PDF

Evaluation of a point-of-care test for quantitative determination of total thyroxine in feline serum.

J Feline Med Surg

January 2025

Department of Veterinary Medicine and Animal Sciences (DIVAS), University of Milan, Lodi (LO), Italy.

Objectives: Total thyroxine (TT4) evaluation is the most commonly used first-line test for the diagnosis and monitoring of cats with hyperthyroidism. Vcheck T4 is a point-of-care immunoassay that measures TT4 using a Vcheck V200 analyser. This study aimed to evaluate the analytic performance of the Vcheck T4 assay in feline sera and the agreement in the classification of normal, high and low TT4 concentrations of Vcheck T4 with those measured by an enzyme immunoassay (EIA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!