A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A randomized trial of continuous glucose monitoring to improve post-transplant glycemic control. | LitMetric

Introduction: This study examines whether the use of inpatient Continuous Glucose Monitors provides improved glycemic control over finger-stick glucose monitoring post-transplant.

Methods: This is a single-site, prospective randomized controlled trial of 40 patients receiving conventional finger-stick glucose monitoring or continuous monitoring using the Medtronic Guardian Sensor 3 during the first 5 days post-transplant. Included patients were adult renal transplant recipients with a diagnosis of diabetes. Assessed endpoints included post-transplant daily median glucose level, hyperglycemic (≥180 mg/dL) and hypoglycemic (≤80 mg/dL) episodes, number of post-transplant bacterial infections and length of stay.

Results: Groups were well matched in demographic variables. Median daily glucose was significantly lower in the intervention group. There were also significantly less episodes of hyperglycemia on postoperative days 2, 3, 4, and 5. There were no differences in the incidences of hypoglycemia, postoperative bacterial infections, or length of stay.

Conclusion: In this randomized study, the use of a continuous glucose monitor to guide post-transplant glucose management significantly lowered the incidence of hyperglycemic episodes and median glucose levels through the first 5 days post-transplant without increasing the number of hypoglycemic episodes. The use of these devices can be considered in the immediate post-renal transplant setting.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ctr.15139DOI Listing

Publication Analysis

Top Keywords

continuous glucose
12
glucose monitoring
12
glucose
9
glycemic control
8
finger-stick glucose
8
5 days post-transplant
8
median glucose
8
bacterial infections
8
infections length
8
post-transplant
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!