A 28-year-old male with atrial fibrillation and thyrotoxicosis-induced heart failure underwent multiple interventions, including extracorporeal membrane oxygenation (ECMO), multiple valve repair/replacement, and Impella placement/removal. However, after a period of three years, the patient developed progressive aortic insufficiency (AI), which was attributed to damage caused by the prolonged use of the Impella device. The discussion highlights the importance of adhering to manufacturer guidelines for device use and emphasizes the need for careful examination during placement to minimize potential complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10505493PMC
http://dx.doi.org/10.7759/cureus.43699DOI Listing

Publication Analysis

Top Keywords

aortic insufficiency
8
subclinical aortic
4
insufficiency causing
4
causing cardiogenic
4
cardiogenic shock
4
shock years
4
years impella
4
impella placement
4
placement 28-year-old
4
28-year-old male
4

Similar Publications

Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.

Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.

View Article and Find Full Text PDF

Infective endocarditis (IE) in children is a rare entity which presents a high rate of events during follow-up. Congenital heart disease, i particular ventricular septal defect (VSD), is the main predisposing condition to IE at those ages. The long-term risk of IE is of concern and whose follow-up can be complicated by a relapse of IE and reintervention.

View Article and Find Full Text PDF

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Objectives: While valve-sparing aortic root replacement (VSRR) has demonstrated satisfactory outcomes, its utility in a reoperative sternotomy setting remains uncertain. This study evaluates the perioperative safety and long-term durability of reoperative sternotomy VSRR.

Methods: All consecutive VSRR at two centers from 2005-2020 were included.

View Article and Find Full Text PDF

Severe mitral regurgitation (MR) following surgical repair of the mitral valve poses a significant clinical challenge. Patients who have undergone surgery are typically at high risk for a second operation. This report details the case of a 54-year-old male who underwent aortic valve replacement and mitral valve repair using a 34-ring, 14 years prior.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!