AI Article Synopsis

  • The study investigates whether the supine transfer test can effectively predict fluid responsiveness in adult patients with acute circulatory failure who do not have intra-abdominal hypertension, by measuring changes in cardiac index (CI).
  • Conducted in a surgical intensive care unit, the study involved 34 patients undergoing a protocol that included measuring CI at different body positions and during a fluid challenge with saline.
  • Results showed a strong correlation (r = 0.73) between changes in CI from the supine transfer test and fluid challenges, indicating that the test can predict fluid responsiveness with 76.5% sensitivity and 88.2% specificity.

Article Abstract

Background: The reversible maneuver that mimics the fluid challenge is a widely used test for evaluating volume responsiveness. However, passive leg raising (PLR) does have certain limitations. The aim of the study is to determine whether the supine transfer test could predict fluid responsiveness in adult patients with acute circulatory failure who do not have intra-abdominal hypertension, by measuring changes in cardiac index (CI).

Methods: Single-center, prospective clinical study in a 25-bed surgery intensive care unit at the Fudan University Shanghai Cancer Center. Thirty-four patients who presented with acute circulatory failure and were scheduled for fluid therapy. Every patient underwent supine transfer test and fluid challenge with 500 mL saline for 15-30 min. There were four sequential steps in the protocol: (1) baseline-1: a semi-recumbent position with the head of the bed raised to 45°; (2) supine transfer test: patients were transferred from the 45° semi-recumbent position to the strict supine position; (3) baseline-2: return to baseline-1 position; and (4) fluid challenge: administration of 500 mL saline for 15-30 min. Hemodynamic parameters were recorded at each step with arterial pulse contour analysis (ProAQT/Pulsioflex). A fluid responder was defined as an increase in CI ≥ 15% after fluid challenge. The receiver operating characteristic curve and gray zone were defined for CI.

Results: Seventeen patients were fluid challenge. The r value of the linear correlations was 0.73 between the supine transfer test- and fluid challenge-induced relative CI changes. The relative changes in CI induced by supine transfer in predicting fluid responsiveness had an area under the receiver operating characteristic curve of 0.88 (95% confidence interval 0.72-0.97) and predicted a fluid responder with 76.5% (95% confidence interval 50.1-93.2) sensitivity and 88.2% (95% confidence interval 63.6-98.5) specificity, at a best threshold of 5.5%. Nineteen (55%) patients were in the gray zone (CI ranging from -3 and 8 L/min/m).

Conclusion: The supine transfer test can potentially assist in detecting fluid responsiveness in patients with acute circulatory failure without intra-abdominal hypertension. Nevertheless, the small threshold and the 55% gray zone were noteworthy limitation.

Trial Registration: Predicting fluid responsiveness with supine transition test (ChiCTR2200058264). Registered 2022-04-04 and last refreshed on 2023-03-26, https://www.chictr.org.cn/showproj.html?proj=166175 .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10506238PMC
http://dx.doi.org/10.1186/s12871-023-02280-0DOI Listing

Publication Analysis

Top Keywords

supine transfer
28
fluid responsiveness
20
fluid challenge
20
transfer test
16
fluid
14
intra-abdominal hypertension
12
acute circulatory
12
circulatory failure
12
gray zone
12
95% confidence
12

Similar Publications

Comprehensive risk assessment of the patient transfer task using the walking belt and floor lift.

Disabil Rehabil Assist Technol

January 2025

Neurorehabilitation Engineering and Assistance Systems Research (NEAR), School of Mechanical Engineering, Universiti Sains Malaysia, Penang, Malaysia.

Work-related musculoskeletal disorders (WMSDs) during bed-to-wheelchair and wheelchair-to-commode transfers are a significant concern, yet prior assessments often focused on specific subtasks, overlooking potential cumulative risks. This study employed Xsens Inertial Measurement Units (IMUs) and force plates integrated with an automated Rapid Entire Body Assessment (REBA) system to provide a continuous and comprehensive evaluation of WMSDs risks associated with the use of a walking belt and a floor lift. The continuous assessment revealed peak REBA scores ranging from 8.

View Article and Find Full Text PDF

A 75-year-old patient with autosomal dominant polycystic kidney disease (ADPKD) and hypertension was admitted to the hospital with abdominal pain secondary to a choledochal cyst resulting in biliary dilation. His hospital course was complicated by pneumonia, encephalopathy, and lower gastrointestinal bleeding (LGIB) that initially did not lead to hemodynamic compromise. To further evaluate the LGIB, a colonoscopy was performed, during which he experienced significant hypotension after being placed in the supine position and given anesthesia.

View Article and Find Full Text PDF

Introduction: By combining nerve and tendon transfer procedures, a more versatile hand function can be expected. Here we report the long-term outcomes of novel, individualized reconstruction strategies using combined nerve and tendon transfer procedures (CNaTT) to restore prehension and grasp in two patients with tetraplegia.

Case Presentation: Two women, 45 years of age, underwent bilateral nerve transfer according to the Bertelli S-PIN (supinator to posterior interosseous nerve transfer) procedure.

View Article and Find Full Text PDF

Objectives: Radiotherapy manages pancreatic cancer in various settings; however, the proximity of gastrointestinal (GI) luminal organs-at-risk (OAR) poses challenges to conventional radiotherapy. Proton beam therapy (PBT) may reduce toxicities compared to photon therapy. This consensus statement summarizes PBT's safe and optimal delivery for pancreatic tumors.

View Article and Find Full Text PDF

Postanesthesia Sling Lift Transfer and Upright Extubation of an Adult Secured in a Motorized Wheelchair: A Case Report.

A A Pract

January 2025

Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota.

This case report describes a 29-year-old patient with cerebral palsy whose mother, for safety reasons, requested that before extubation in the postanesthesia care unit, her son be transferred from the padded stretcher to his personal motorized wheelchair. Using a sling lift, we safely transferred the anesthetized, intubated patient from a supine position to an upright sitting position. Although sling lifts are often used in critical care and rehabilitation environments, use in the perioperative space is rare.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!