A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Paper-based microfluidic device for selective detection of peanut allergen Ara h1 applying black phosphorus-Au nanocomposites for signal amplification. | LitMetric

Paper-based microfluidic device for selective detection of peanut allergen Ara h1 applying black phosphorus-Au nanocomposites for signal amplification.

Talanta

State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China; Key Laboratory of Food Quality and Health of Tianjin, Tianjin University of Science & Technology, 300457, Tianjin, China. Electronic address:

Published: January 2024

This paper developed a portable microfluidic paper-based analysis device (μ-PAD) combined with the electrochemical technique for efficient and sensitive detection of peanut allergen Ara h1. The proposed μ-PAD works based on the variation of differential pulse voltammetry (DPV) response current induced by peanut allergen Ara h1. Black phosphorus (BP)-Au nanocomposites were introduced both to improve the electron transfer rate at the electrode interface for signal amplification, and to immobilize the specific Ara h1 aptamers through Au-S bonding to recognize the target in food matrices. This μ-PAD had good specificity and detection stability for Ara h1 allergen and could complete the entire analysis process within 20 min, achieving a wide linear response range (25-800 ng mL) and a low detection limit (LOD, 11.8 ng mL). In the Ara h1 allergen detection applied to real peanut products (cookies, milk, and bread), the constructed μ-PAD obtained acceptable recoveries (93.50%-101.86%) with relative standard deviations (RSDs) of 0.36-2.97% (n = 3), with a good correlation with the ELISA results (R = 0.9956). Therefore, the portable μ-PAD based on BP-Au nanocomposites was demonstrated to provide an effective strategy for rapid analysis and screening of Ara h1 allergen in food, which has broad application prospects.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2023.125188DOI Listing

Publication Analysis

Top Keywords

peanut allergen
12
allergen ara
12
ara allergen
12
detection peanut
8
signal amplification
8
bp-au nanocomposites
8
ara
7
allergen
6
detection
5
μ-pad
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!