Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Qualifying critical reagents in ligand binding assays by parallel testing of current and candidate reagent lots is recommended by regulatory agencies and industry groups, but specific guidance on the format of reagent qualification experiments is limited. Equivalence testing is a statistically sound approach that is consistent with the objective of critical reagent qualification. We present power analysis for equivalence regions ranging from 1.25- to 1.5-fold multiples of the GM ratio (centered on 1) of current and candidate lots, over a range of assay variability from 5 to 30% coefficient of variation (CV). A 1.25-fold equivalence region can be tested using 6 to 12 plates per lot for assays with up to 15% CV but is not practical for more variable assays. For these assays, wider equivalence regions are justified so long as care is taken to avoid assay drift and the assay remains suitable for the intended use. The equivalence test method is illustrated using historical data from passing and failing reagent qualification experiments. Simulation analysis was performed to support the design of qualification experiments using 6, 12, or 18 plates per lot over a broad range of assay variability. A challenge in implementing the equivalence test approach is selecting an appropriate equivalence region. Equivalence regions providing 90% power using 12 plates/lot were consistent with 1.5σ bounds, which are recommended for equivalence testing of critical quality attributes of biosimilars.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1208/s12248-023-00857-8 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!