Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To evaluate the optical quality of different toric contact lens (CL) designs and compare their on-eye visual correction performance.
Methods: Twenty soft CL wearers aged 20 to 39 years were enrolled. Two daily disposable silicone-hydrogel toric CLs were tested: the "Eyelid Stabilized Design" (ESD-CL) and prism-ballast design (PB-CL); a spherical daily disposable silicone hydrogel CL (spherical CL) was used as a control. On-eye performance was compared for corrected distance visual acuity (CDVA), astigmatism, and ocular higher-order aberrations (HOAs); astigmatism and ocular HOAs were measured with a wavefront sensor. The subjective quality of vision, rated for "blurred vision" and "double vision," lens rotation, and fitting were also compared.
Results: The ESD-CLs, PB-CL, and no-CL provided better CDVA than spherical CL ( P <0.05). Compared with spherical CL and no CL, PB-CL and ESD-CLs caused significantly lesser astigmatism ( P <0.05). Coma was significantly lesser with ESD-CLs than that with PB-CL ( P <0.05); total HOAs did not differ among the four conditions. The subjective ratings for blurred and double vision were significantly lower with ESD-CLs than those with spherical CL ( P <0.05).
Conclusions: Toric CLs provide a better CDVA than spherical CLs. However, differences in coma and subjective symptoms may occur because of the design of toric CLs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ICL.0000000000001037 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!