Superharmonic contrast imaging (SpHI) suppresses tissue clutter and allows high-contrast visualization of the vasculature. An array-based dual-frequency (DF) probe has been developed for SpHI, integrating a 21-MHz, 256-element microultrasound imaging array with a 2-MHz, 32-element array to take advantage of the broadband nonlinear responses from microbubble (MB) contrast agents. In this work, ultrafast imaging with plane waves was implemented for SpHI to increase the acquisition frame rate. Ultrafast imaging was also implemented for microultrasound B-mode imaging (HFPW B-mode) to enable high-resolution visualization of the tissue structure. Coherent compounding was demonstrated in vitro and in vivo in both imaging modes. Acquisition frame rates of 4.5 kHz and 187 Hz in HFPW B-mode imaging were achieved for imaging up to 21 mm with one and 25 angles, respectively, and 3.5 kHz and 396 Hz in the SpHI mode with one and nine coherently compounded angles, respectively. SpHI images showed suppression of tissue clutter prior to and after the introduction of MBs in vitro and in vivo. The nine-angle coherently compounded 2-D SpHI images of contrast-filled flow channel showed a contrast-to-tissue ratio (CTR) of 26.0 dB, a 2.5-dB improvement relative to images reconstructed from 0° steering. Consistent with in vitro imaging, the nine-angle compounded 2-D SpHI of a Lewis lung cancer tumor showed a 2.6-dB improvement in contrast enhancement, relative to 0° steering, and additionally revealed a region of nonviable tissue. The 3-D display of the volumetric SpHI data acquired from a xenograft mouse tumor using both 0° steering and nine-angle compounding allowed the visualization of the tumor vasculature. A small vessel visible in the compounded SpHI image, measuring around [Formula: see text], is not visualized in the 0° steering SpHI image, demonstrating the superiority of the latter in detecting fine structures within the tumor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10712286PMC
http://dx.doi.org/10.1109/TUFFC.2023.3316120DOI Listing

Publication Analysis

Top Keywords

0° steering
16
imaging
10
sphi
10
microultrasound imaging
8
imaging plane
8
tissue clutter
8
ultrafast imaging
8
acquisition frame
8
b-mode imaging
8
hfpw b-mode
8

Similar Publications

Locomotory Behavior of Water Striders with Amputated Legs.

Biomimetics (Basel)

November 2023

Functional Morphology and Biomechanics, Institute of Zoology, Kiel University, 24118 Kiel, Germany.

The stability of the body during locomotion is a fundamental requirement for walking animals. The mechanisms that coordinate leg movement patterns are even more complex at water-air interfaces. Water striders are agile creatures on the water surface, but they can be vulnerable to leg damage, which can impair their movement.

View Article and Find Full Text PDF

The World Health Organization declared COVID-19 a global pandemic on the 11th of March 2020, but the world is still reeling from its aftermath. Originating from China, cases quickly spread across the globe, prompting the implementation of stringent measures by world governments in efforts to isolate cases and limit the transmission rate of the virus. These measures have however shattered the core sustaining pillars of the modern world economies as global trade and cooperation succumbed to nationalist focus and competition for scarce supplies.

View Article and Find Full Text PDF

Recent reports offer contrasting views on whether or not the use of online visual control is impaired in individuals with developmental coordination disorder (DCD). This study explored the optimal temporal basis for processing and using visual information in adolescents and young adults with DCD. Participants were 22 adolescents and young adults (12 males and 10 females; M = 19 years, SD = 3).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!