Introduction: In left bundle branch area pacing (LBBAP), several methods allow determination of lead depth during active fixation inside the septum: among these, visualization of a Purkinje potential indicates that the subendocardial area has been reached. In LBB block (LBBB) patients, fascicular potentials are visible as presystolic only in rare conditions.
Methods And Results: Since October 2022 until August 2023, LBBAP was attempted in 21 patients with LBBB at our Center: among the 18 consecutive patients (86%) in which it was successful, focusing on the terminal part of the unipolar ventricular electrogram (VEGM) recorded in the LBBA (where fixation beats occurred and conduction system (CS) capture was confirmed), we always observed discrete high-frequency, low-amplitude signals during spontaneous rhythm with LBBB morphology, showing a consistent coupling with the QRS onset, falling in a portion of QRS interval ranging from 58% to 80% of its overall duration, and disappearing during pacing. As found in a recently published case report, these sharp signals could represent the activation of left ventricular CS fibers, occurring passively from the septal working myocardium, and thus appearing lately in the VEGM.
Conclusion: The possibility of recognizing discrete high-frequency, low-amplitude signals within the terminal portion of the unipolar VEGM, possibly representing left CS potentials, even in patients with LBBB, may constitute a useful additional means to notice operators about having reached the LBBA, thus helping to avoid perforation in the left ventricle.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jce.16071 | DOI Listing |
Heart Rhythm
January 2025
Geisinger Heart Institute, Wilkes Barre, PA, USA. Electronic address:
Heart Rhythm
January 2025
Geisinger Heart Institute, Geisinger Wyoming Valley Medical Center, MC 36-10, 1000 E Mountain Blvd, Wilkes-Barre, PA 18711.
J Electrocardiol
January 2025
Victorian Heart Institute, Monash University, Clayton, VIC, Australia; Victorian Heart Hospital, Clayton, VIC, Australia. Electronic address:
Introduction: This study evaluates various formulae used to correct the QT interval in patients with wide QRS complexes to calculate corrected QT (QTc) following Cardiac Resynchronisation Therapy (CRT).
Methods: We included patients with severe heart failure and left bundle branch block, presenting with a QRS duration of at least 120 milliseconds, who underwent successful CRT implantation. Patients were excluded if they had non-lateral left ventricular lead placement, metabolic disorders, atrial fibrillation, atrial tachycardia, or high-degree atrioventricular block prior to implantation.
Int J Environ Res Public Health
January 2025
Study Design and Scientific Writing Laboratory, Centro Universitario FMABC, Santo André 09060-870, SP, Brazil.
The trained heart adapts through geometric changes influenced by concentric and eccentric hypertrophy, depending on the predominance of the isometric or dynamic components of the exercise performed. Additionally, alterations in heart rhythm may occur due to increased vagal system activity. Cardiological evaluation with an electrocardiogram (ECG) aims to identify cardiac conditions that could temporarily or permanently disqualify an athlete from competition.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.
Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.
Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!