Objectives: The reconstruction of bone defects in tibial revision knee arthroplasty is challenging. In this study, we evaluated the primary stability of a novel three-dimensional (3D)-printed custom-made metaphyseal cone for Anderson Orthopedic Research Institute (AORI) IIb or III bone defect reconstruction in tibial revision knee arthroplasty using the combination of finite-element analysis and biomechanical experiments.

Methods: In the finite-element analysis, AORI II b and III medial tibial bone defects were designed at varying depths. A novel 3D-printed custom-made metaphyseal cone was designed and used to reconstruct the bone defect with or without a stem in simulated revision total knee arthroplasty (RTKA). A no-stem group and a stem group were established (based on whether a stem was used or not). Von Mises stress and micromotion were calculated with varying depths of bone defects, ranging from 5 mm to 35 mm, and then micromotions at the bone-implant interface were calculated and compared with the critical value of 150 μm. In the biomechanical experiment, the no-stem group was used, and the same bone defects were made in four synthetic tibias using patient-specific instruments. Micromotions at the bone-implant interface were investigated using a non-contact optical digital image correlation system and compared with the critical value of 150 μm.

Results: When the bone defect was <30 mm, micromotions at the bone-implant interface in the finite-element analysis were all below 150 μm both in the stem groups and no-stem groups, whereas those in the biomechanical experiment were also below 150 μm in the no-stem group.

Conclusions: The 3D-printed custom-made metaphyseal cone in RTKA has excellent primary stability and does not require stems in reconstructing tibial AORI type IIb or III bone defects with a depth of <30 mm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10622292PMC
http://dx.doi.org/10.1111/os.13885DOI Listing

Publication Analysis

Top Keywords

bone defects
20
custom-made metaphyseal
12
metaphyseal cone
12
knee arthroplasty
12
bone defect
12
bone
8
tibial bone
8
analysis biomechanical
8
tibial revision
8
revision knee
8

Similar Publications

The aim of the study was to compare the outcomes of bone transport in treating upper- middle vs. lower- middle tibial bone defects. Sixty-two patients with tibial infected large segmental defects treated by bone transport were analyzed retrospectively and divided into distal group (lower- middle tibial bone defects and proximal transport, n=38) and proximal group (upper- middle tibial bone defects and distal transport, n=24).

View Article and Find Full Text PDF

Semiconductor photocatalytic antibacterial materials and their application for bone infection treatment.

Nanoscale Horiz

January 2025

State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China.

Bacterial infection in bone tissue engineering is a severe clinical issue. Traditional antimicrobial methods usually cause problems such as bacterial resistance and biosecurity. Employing semiconductor photocatalytic antibacterial materials is a more controlled and safer strategy, wherein semiconductor photocatalytic materials generate reactive oxygen species under illumination for killing bacteria by destroying their cell membranes, proteins, DNA, In this review, P-type and N-type semiconductor photocatalytic materials and their antibacterial mechanisms are introduced.

View Article and Find Full Text PDF

Background: Soft tissue defects on the palm side of the thumb can be effectively covered by using the radial midpalmar (RMP) flap, which is usually harvested as a pedicled flap. However, previous anatomical studies on this flap are limited. We analyzed multidetector-row computed tomography angiograms of the radial midpalm of hands to more precisely characterize the 3-dimensional anatomical structure of the perforators in living patients.

View Article and Find Full Text PDF

Management of periacetabular osteolysis is a challenging dilemma in revision total hip arthroplasty. When the acetabular shell is well-fixed, the surgeon may prefer to retain the cup to minimize further bone loss. However, filling the surrounding defect can be difficult if the area of involvement is massive.

View Article and Find Full Text PDF

Bolstered bone regeneration by multiscale customized magnesium scaffolds with hierarchical structures and tempered degradation.

Bioact Mater

April 2025

Department of Orthopedic Surgery, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China.

Addressing irregular bone defects is a formidable clinical challenge, as traditional scaffolds frequently fail to meet the complex requirements of bone regeneration, resulting in suboptimal healing. This study introduces a novel 3D-printed magnesium scaffold with hierarchical structure (macro-, meso-, and nano-scales) and tempered degradation (microscale), intricately customized at multiple scales to bolster bone regeneration according to patient-specific needs. For the hierarchical structure, at the macroscale, it can feature anatomic geometries for seamless integration with the bone defect; The mesoscale pores are devised with optimized curvature and size, providing an adequate mechanical response as well as promoting cellular proliferation and vascularization, essential for natural bone mimicry; The nanoscale textured surface is enriched with a layered double hydroxide membrane, augmenting bioactivity and osteointegration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!