A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Motives for using electronic nicotine delivery systems (ENDS) as a cessation tool are associated with tobacco abstinence at 1-year follow-up: A prospective investigation among young adults in the United States Air Force. | LitMetric

Introduction: Smokers use electronic nicotine delivery systems (ENDS), including e-cigarettes, as a harm reduction strategy even though the Food and Drug Administration (FDA) has not approved them for tobacco cessation. The limited literature about ENDS use for cigarette cessation is concerning for the U.S. military, which is largely comprised of young adults at increased risk for tobacco use. Thus, the current study aims to evaluate use of ENDS products as a cessation tool in relation to point-prevalence tobacco abstinence at one-year follow-up in a cohort of 8,901 U.S. Air Force personnel attending entry-level job training from March 2016 to April 2019.

Methods: A propensity-score adjusted multinomial logistic regression model was used to assess the association between the baseline motives for ENDS use (i.e., for cigarette cessation versus alternative reasons) and tobacco use at the one-year follow-up (cigarette use, non-cigarette tobacco product use, and tobacco abstinence) among those reporting history of cigarette use at baseline.

Results: Smokers reporting ENDS use for cigarette cessation were more likely to be abstinent at one-year follow-up (Odds Ratio[OR] = 1.62, 95% CI: 1.06-2.49,  =.03) as well as quit using non-cigarette tobacco products (OR = 2.11, 95% CI: 1.65-2.70,  <.001) than those reporting ENDS use for alternative reasons.

Conclusions: Current tobacco users are recommended to use FDA-approved products for smoking cessation, such as nicotine replacement therapy. However, given the high prevalence of cigarette use among military populations, ENDS may provide a useful alternative harm reduction strategy for this high-risk population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10498292PMC
http://dx.doi.org/10.1016/j.pmedr.2023.102399DOI Listing

Publication Analysis

Top Keywords

tobacco abstinence
12
ends cigarette
12
cigarette cessation
12
one-year follow-up
12
electronic nicotine
8
nicotine delivery
8
delivery systems
8
systems ends
8
cessation tool
8
tobacco
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!