Background: Angio-based index of microcirculatory resistance (IMR) and fractional flow reserve (FFR) have been developed, however, the differences between baseline and hyperemic data and their effects on their computation have not yet been discussed. This study aimed to compare the diagnostic performance of a novel method for calculating IMR and FFR from coronary angiography under baseline and hyperemic conditions.

Methods: We performed a retrospective study to investigate the diagnostic performance of angiography-derived IMR (AccuIMR) and FFR (AccuFFRangio) computed from the hyperemic condition (AccuIMR, AccuFFRangio) and baseline condition (AccuIMR, AccuFFRangio) in 101 consecutive patients with chronic coronary syndrome (CCS) who underwent measurements of IMR and FFR at a single center, using wire-based IMR and FFR as the reference standard.

Results: AccuIMR showed much better correlation with IMR than AccuIMR (r=0.77 0.47, P<0.001). The diagnostic accuracy and area under the curve (AUC) for identifying significant microvascular dysfunction was higher for AccuIMR than AccuIMR [92.1% (95% CI: 85.0-96.5%) 83.2% (95% CI: 74.4-89.9%), P=0.012; 0.942 (95% CI: 0.877-0.979) 0.815 (95% CI: 0.726-0.886), P=0.003]. The computed AccuFFRangio showed good correlations with FFR and good diagnostic performance under both hyperemic and baseline conditions [r=0.68 0.68, P>0.99; diagnostic accuracy =95.9% (95% CI: 89.8-98.9%) 94.9% (95% CI: 88.4-98.3%), P=0.728; AUC =0.989 (95% CI: 0.942-1.000) 0.973 (95% CI: 0.919-0.995), P=0.381]. The net reclassification index (NRI) demonstrated that hyperemic group had improved reclassification ability compared to the baseline group in identification of IMR >25 (NRI =0.20, P<0.001) and FFR ≤0.8 (NRI =0.11, P<0.001).

Conclusions: By comparing the calculated angio-derived IMR and FFR under the baseline and hyperemic conditions, this study demonstrates that AccuIMR calculation is more accurate using the hyperemic condition, while AccuFFRangio calculation is accurate under both conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10498260PMC
http://dx.doi.org/10.21037/qims-23-72DOI Listing

Publication Analysis

Top Keywords

imr ffr
12
angio-based microcirculatory
8
microcirculatory resistance
8
fractional flow
8
baseline hyperemic
8
diagnostic performance
8
imr accuimr
8
condition accuimr
8
accuimr accuffrangio
8
imr
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!