A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative HPTLC study for simultaneous determination of ivabradine and metoprolol using UV and fluorescence detectors. | LitMetric

Comparative HPTLC study for simultaneous determination of ivabradine and metoprolol using UV and fluorescence detectors.

BMC Chem

Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, 11795, Cairo, Egypt.

Published: September 2023

New, simple, accurate, sensitive and validated high performance thin layer chromatographic (HPTLC) method coupled with UV absorbance mode and fluorescence (FL) detectors which were used for simultaneous determination of ivabradine (IVA) and metoprolol (MET) in their bulk and pharmaceutical dosage form using TLC silica 60 F plates and non-fluorescent TLC silica gel 60 plates. The developing system was chloroform: methanol: formic acid: ammonia (8.5:1.5:0.2:0.1, v/v). Desnitometric analysis in UV absorbance mode was set at λ = 275 nm. While, fluorescence mode was performed with excitation at 260 nm for quantitative simultaneous determination of IVA and MET using optical filter K320. The retention factors values were 0.45 ± 0.05 and 0.89 ± 0.01 of IVA and MET, respectively. UV absorbance mode, linearity was 50.0-600.0 ng/band for IVA and 50.0-900.0 ng/band for MET. For fluorescence mode, the linearity ranges were 18.0-400.0 ng/band and 50.0-550.0 ng/band for IVA and MET; respectively. ICH guidelines were followed in respect to linearity and range, accuracy, precision and selectivity, limit of detection (LOD), limit of quantitation (LOQ) and robustness. The analytical eco-scale, green analytical procedure index (GAPI) and analytical greenness metric tools were used to assess the suggested method. The quantitative proposed method results showed there was no statistically significant difference at 95% confidence when compared to the reported method of high performance liquid chromatography (HPLC).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10500752PMC
http://dx.doi.org/10.1186/s13065-023-01025-xDOI Listing

Publication Analysis

Top Keywords

simultaneous determination
12
absorbance mode
12
iva met
12
determination ivabradine
8
fluorescence detectors
8
high performance
8
tlc silica
8
fluorescence mode
8
mode linearity
8
mode
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!