We aimed to compare the ability of carotid corrected flow time assessed by ultrasound and the changes in dynamic preload indices induced by tidal volume challenge predicting fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. This prospective single-center study included patients undergoing robot-assisted laparoscopic surgery in the modified head-down lithotomy position. Carotid Doppler parameters and hemodynamic data, including corrected flow time, pulse pressure variation, stroke volume variation, and stroke volume index at a tidal volume of 6 mL/kg predicted body weight and after increasing the tidal volume to 8 mL/kg predicted body weight (tidal volume challenge), respectively, were measured. Fluid responsiveness was defined as a stroke volume index ≥ 10% increase after volume expansion. Among the 52 patients included, 26 were classified as fluid responders and 26 as non-responders based on the stroke volume index. The area under the receiver operating characteristic curve measured to predict the fluid responsiveness to corrected flow time and changes in pulse pressure variation (ΔPPV) after tidal volume challenge were 0.82 [95% confidence interval (CI) 0.71-0.94; P < 0.0001] and 0.85 (95% CI 0.74-0.96; P < 0.0001), respectively. The value for pulse pressure variation at a tidal volume of 8 mL/kg was 0.79 (95% CI 0.67-0.91; P = 0.0003). The optimal cut-off values for corrected flow time and ΔPPV were 357 ms and > 1%, respectively. Both the corrected flow time and Changes in pulse pressure variation after tidal volume challenge reliably predicted fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. And pulse pressure variation at a tidal volume of 8 mL/kg maybe also a useful predictor.Trial registration: Chinese Clinical Trial Register (CHiCTR2200060573, Principal investigator: Hongliang Liu, Date of registration: 05/06/2022).

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11701-023-01710-yDOI Listing

Publication Analysis

Top Keywords

tidal volume
24
corrected flow
16
flow time
16
volume challenge
16
fluid responsiveness
16
stroke volume
16
robot-assisted laparoscopic
12
volume
11
carotid corrected
8
laparoscopic surgery
8

Similar Publications

Feasibility and safety of ultra-low volume ventilation (≤ 3 ml/kg) combined with extra corporeal carbon dioxide removal (ECCOR) in acute respiratory failure patients.

Crit Care

December 2024

Department of Anesthesia and Intensive Care Unit, Regional University Hospital of Montpellier, St-Eloi Hospital, PhyMedExp, INSERM U1046, CNRS UMR, University of Montpellier, 9214, Montpellier Cedex 5, France.

Background: Ultra-protective ventilation is the combination of low airway pressures and tidal volume (Vt) combined with extra corporeal carbon dioxide removal (ECCOR). A recent large study showed no benefit of ultra-protective ventilation compared to standard ventilation in ARDS (Acute Respiratory Distress Syndrome) patients. However, the reduction in Vt failed to achieve the objective of less than or equal to 3 ml/kg predicted body weight (PBW).

View Article and Find Full Text PDF

Aim: Intraoperative lung-protective ventilation strategies (LPVS) have been shown to improve lung oxygenation and prevent postoperative pulmonary problems in surgical patients. However, the application of positive end-expiratory pressure (PEEP)-based LPVS in emergency traumatic brain injury (TBI) has not been thoroughly explored. The purpose of this study is to evaluate the effects of drive pressure-guided individualized PEEP on perioperative pulmonary oxygenation, postoperative pulmonary complications, and recovery from neurological injury in patients with TBI.

View Article and Find Full Text PDF

Introduction: Although noninvasive monitoring through quantifying rib cage movement has been useful in serial assessment of pulmonary function in newborns, measuring tidal volume (TV) is commonly performed invasively. As it is the most basic measure of pulmonary function, expanding its assessment to a noninvasive measure can contribute to clinical findings and interpretations in neonatal clinical practice.

Objective: (1) Create a noninvasive measurement tool for TV for neonatal clinical use; (2) Evaluate the agreement between measured TV and predicted TV.

View Article and Find Full Text PDF

Objective: To assess the impact of mild hypothermia on the distribution and elimination of an IV crystalloid fluid bolus in healthy anesthetized cats using volume kinetic (VK) analysis.

Methods: 10 adult cats were anesthetized and included in a prospective, randomized, cross-over study. The subjects were maintained either normothermic (38.

View Article and Find Full Text PDF

Increasing evidence indicates an association between microbiome composition and respiratory homeostasis and disease, particularly disordered breathing, such as obstructive sleep apnea. Previous work showing respiratory disruption is limited by the methodology employed to disrupt, eliminate, or remove the microbiome by antibiotic depletion. Our work utilized germ-free mice born without a microbiome and described respiratory alterations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!