An extrinsic fiber optic Fabry-Perot interferometric (EFPI) ultrasonic sensor based on a grooved silicon diaphragm for partial discharge (PD) detection has been proposed. The size of the groove is determined by finite element simulation, which allows the resonant frequency of the sensor to meet the requirements of PD ultrasonic detection and improves the sensitivity of the sensor by 5.07 times compared with that based on a traditional circular diaphragm. The microelectro-mechanical system process is used to fabricate the diaphragm on a silicon-on-insulator wafer, and the prepared diaphragm has a grooved section with a diameter of 829.34 µm and a thickness of only 2.09 µm. At its resonant frequency of 61.5 kHz, the acoustic pressure sensitivity of the sensor is 172.42 mV/Pa. The ultrasonic signal detection capability of the sensor is verified in the PD experiment. Furthermore, the characteristics of the corona discharge are successfully manifested based on the ultrasonic waves detected by the EFPI sensor. It is demonstrated that the proposed sensor is suitable for PD detection due to its high sensitivity, simple production process, and good resistance to environmental interference.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.494459 | DOI Listing |
Expert Rev Med Devices
January 2025
Joint Shantou International Eye Center, Shantou University and the Chinese University of Hong Kong, Shantou, Guangdong, China.
Objective: To explore the impact of glaucoma on the retinal nerve fiber layer (RNFL) optical density ratio (ODR) by volumetric optical coherence tomography (OCT) under different analytical radii.
Methods: Twenty-five eyes identified as healthy and 57 eyes with a glaucoma diagnosis (23 mild and 34 moderate-advanced cases) underwent volumetric OCT scans centered at the optic nerve head. Cross-sectional images were obtained through 5 distinct analytical circles with varying radii.
BMC Ophthalmol
January 2025
Department of Ophthalmology, University of Health Sciences, Izmir Bozyaka Education and Research Hospital, Bahar Mah. Saim Çıkrıkcı Cad No: 59, Karabağlar, Turkey.
Background: The aim of the present study was to compare the rates of change in Ganglion Cell- Inner Plexiform Layer (GCIPL) and Retinal Nerve Fiber Layer (RNFL) thickness, as measured by Optical Coherence Tomography (OCT) Guided Progression Analysis (GPA) program in control group, Primary Open Angle Glaucoma (POAG) and Pseudoexfoliation Glaucoma (PXG) eyes.
Methods: 60 POAG and 60 PXG patients and 30 control group patients were included in the study. Patients diagnosed with glaucoma were divided into two groups as mild (Mean deviation (MD) > -6.
J Med Imaging (Bellingham)
January 2025
University of Arizona, College of Biomedical Engineering, Tucson, Arizona, United States.
Purpose: Diffusion magnetic resonance imaging (dMRI) quantitatively estimates brain microstructure, diffusion tractography being one clinically utilized framework. To advance such dMRI approaches, direct quantitative comparisons between microscale anisotropy and orientation are imperative. Complete backscattering Mueller matrix polarized light imaging (PLI) enables the imaging of thin and thick tissue specimens to acquire numerous optical metrics not possible through conventional transmission PLI methods.
View Article and Find Full Text PDFAnal Chem
January 2025
School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning, China.
A cantilever-enhanced fiber-optic photoacoustic (PA) spectrophone is reported for trace gas detection at a low-pressure environment. A cantilever-based fiber-optic Fabry-Perot (F-P) interferometer (FPI) is utilized for simultaneous measurement of air pressure and PA pressure. Since the cantilever resonance frequency follows air pressure linearly, the fundamental frequency intensity modulation (1-IM) technique is applied to scan the frequency response of the solid PA signal from tube wall absorption for tracking the cantilever resonance frequency in real time.
View Article and Find Full Text PDFFront Med (Lausanne)
December 2024
Department of Anaesthesiology and Intensive Therapy, Medical University of Lodz, Łódź, Poland.
Background: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway.