A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Paper-Based All-in-One Origami Nanobiosensor for Point-of-Care Detection of Cardiac Protein Markers in Whole Blood. | LitMetric

Rapid and accurate diagnosis of cardiovascular diseases (CVDs) at the earliest stage is of paramount importance to improve the treatment outcomes and avoid irreversible damage to a patient's cardiovascular system. Microfluidic paper-based devices (μPADs) represent a promising platform for rapid CVD diagnosis at the point of care (POC). This paper presents an electrochemical μPAD (E-μPAD) with an all-in-one origami design for rapid and POC testing of cardiac protein markers in whole blood. Based on the label-free, electrochemical impedance spectroscopy (EIS) immunoassay, the E-μPAD integrates all essential components on a single chip, including three electrochemical cells, a plasma separation membrane, and a buffer absorption pad, enabling easy and streamlined operations for multiplexed detection of three cardiac protein markers [cardiac troponin I (cTnI), brain natriuretic peptide (BNP)-32, and D-Dimer] on a finger-prick whole blood sample within 46 min. Superior analytical performance is achieved through sensitive EIS measurement on carbon electrodes decorated with semiconductor zinc oxide nanowires (ZnO NWs). Using spiked human plasma samples, ultralow limits of detection (LODs) of E-μPAD are achieved at 4.6 pg/mL (190 fM) for cTnI, 1.2 pg/mL (40 fM) for BNP-32, and 146 pg/mL (730 fM) for D-Dimer. Real human blood samples spiked with purified proteins are also tested, and the device's analytical performance was proven to be comparable to commercial ELISA kits. The all-in-one E-μPAD will allow rapid and sensitive testing of cardiac protein markers through easy operations, which holds great potential for on-site screening of acute CVDs in nonlaboratory settings such as emergency rooms, doctor's offices, or patient homes.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.3c01221DOI Listing

Publication Analysis

Top Keywords

cardiac protein
16
protein markers
16
all-in-one origami
8
markers blood
8
testing cardiac
8
analytical performance
8
paper-based all-in-one
4
origami nanobiosensor
4
nanobiosensor point-of-care
4
point-of-care detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!