A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Exergo-enviro-economic and yearly productivity analyses of conical passive solar still for sustainable solar distillation. | LitMetric

This paper focuses on exergo-enviro-economic and yearly productivity analyses for conical passive solar still having the potential to fulfil the sustainable development goal of the United Nations. A new approach for thermal modelling of conical passive solar still has been carried out with experimental validation in the present work, wherein different weather conditions have been considered for the analysis of the proposed system. The carried out work has been done for each month of the year. In further methodology, the computational code in MATLAB has been used for the computation of hourly freshwater production, exergy, and energy followed by the estimation of their annual values. Thereafter, exergo-enviro-economic parameters, yearly productivity, payback period, and freshwater cost have been estimated, and the obtained results have been compared with the earlier published research. Concludingly, the exergo-economic parameter, enviro-economic parameter, and yearly productivity for the proposed system have been found higher by 44.25%, 25.68%, and 44.07%, respectively, than the conventional solar still. The comparative freshwater cost is 13.56% less than the conventional solar still for 0.025 m water depth. Additionally, the payback period for the proposed system will remain at 2.75 years, which is 13.82% less in comparison to the conventional solar still considering a 2% interest rate.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-023-29519-0DOI Listing

Publication Analysis

Top Keywords

yearly productivity
16
conical passive
12
passive solar
12
proposed system
12
conventional solar
12
exergo-enviro-economic yearly
8
productivity analyses
8
analyses conical
8
payback period
8
freshwater cost
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!