Purpose: To compare the predictive accuracy of the biometer-embedded Barrett True-K TK and new total corneal power methods of intraocular lens (IOL) power calculation in eyes with prior laser vision correction (LVC) for myopia.
Setting: Academic clinical practice.
Design: Retrospective case series.
Methods: IOL power formulas were assessed using measurements from a swept-source optical coherence biometer. Refractive prediction errors were calculated for the Barrett True-K TK, EVO 2.0, Pearl-DGS, and HofferQST, which use both anterior and posterior corneal curvature measurements. These were compared with the Shammas, Haigis-L, Barrett True-K No History (NH), optical coherence tomography, and 4-formula average (AVG-4) on the ASCRS postrefractive calculator, and to the Holladay 1 and 2 with non linear axial length regressions (H1- and H2-NLR).
Results: The study comprised 85 eyes from 85 patients. Only the Barrett True-K TK and EVO 2.0 had mean numerical errors that were not significantly different from 0. The EVO 2.0, Barrett True-K TK, Pearl-DGS, AVG-4, H2-NLR, and Barrett True-K NH were selected for further pairwise analysis. The Barrett True-K TK and EVO 2.0 demonstrated smaller root-mean-square absolute error compared with the Pearl-DGS, and the Barrett True-K TK also had a smaller mean absolute error than the Pearl-DGS.
Conclusions: The Barrett True-K TK and EVO 2.0 formulas had comparable performance to existing formulas in eyes with prior myopic LVC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/j.jcrs.0000000000001300 | DOI Listing |
Clin Ophthalmol
December 2024
Alcon Vision LLC, Fort Worth, TX, USA.
Purpose: To compare the refractive prediction accuracy of the Optiwave Refractive Analysis (ORA) SYSTEM with the Barrett True-K (BTK) formula in calculating intraocular lens (IOL) power in eyes that underwent cataract surgery after previous myopic photorefractive keratectomy (PRK) or laser-assisted in situ keratomileusis (LASIK).
Methods: This retrospective study evaluated patients aged ≥22 years with prior myopic PRK or LASIK who underwent unilateral or bilateral cataract removal and monofocal IOL implantation using the ORA SYSTEM at 177 sites in the United States. Two datasets were analyzed: All Eyes (ie, all eligible eyes) and First Surgery Eyes (ie, each patient's first implanted eye).
Clin Exp Ophthalmol
December 2024
Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Background: Accurate intraocular lens (IOL) calculation in eyes with keratoconus (KCN) poses significant challenges. While various formulas, including KCN-specific ones, have been investigated, the optimal calculation method remains inconclusive.
Methods: The study was pre-registered in PROSPERO (CRD42023483119).
Int Ophthalmol
November 2024
Anterior Segment Surgery Department, Asociación Para Evitar La Ceguera en México I.A.P., Vicente García Torres 46, Barrio San Lucas, CP 04030, Coyoacán, Mexico City, Mexico.
Purpose: To describe the accuracy of monofocal intraocular lens power calculation in patients with keratoconus using total keratometry (TK) and standard keratometry (K) with conventional and keratoconus-modified formulas.
Setting: Asociación Para Evitar la Ceguera en México, Mexico City, Mexico.
Design: Observational, retrospective, non-randomized, comparative study.
Sci Rep
November 2024
Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan.
This retrospective study compared postoperative prediction errors of recent formulas using standard- or total keratometry (K or TK) for intraocular lens (IOL) power calculation in post-myopic LASIK patients. It included 56 eyes of 56 patients who underwent uncomplicated cataract surgery, with at least 1-month follow-up at Keio University Hospital in Tokyo or Hayashi Eye Hospital in Yokohama, Japan. Prediction errors, absolute errors, and percentage of eyes with prediction errors within ± 0.
View Article and Find Full Text PDFFront Med (Lausanne)
October 2024
Optics and Optometry and Vision Sciences Department, University of Valencia, Valencia, Spain.
Background: To compare the accuracy of intraoperative wavefront aberrometry using the ORA VLynk system with different biometry-based formulas in short and long eyes after cataract surgery.
Methods: This prospective study considered 48 eyes with axial lengths of <22.1 mm and 48 eyes with axial lengths of >25.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!