Significance: Quantifying the biomechanical properties of the whole eye globe can provide a comprehensive understanding of the interactions among interconnected ocular components during dynamic physiological processes. By doing so, clinicians and researchers can gain valuable insights into the mechanisms underlying ocular diseases, such as glaucoma, and design interventions tailored to each patient's unique needs.
Aim: The aim of this study was to evaluate the feasibility and effectiveness of a multifocal acoustic radiation force (ARF) based reverberant optical coherence elastography (RevOCE) technique for quantifying shear wave speeds in different ocular components simultaneously.
Approach: We implemented a multifocal ARF technique to generate reverberant shear wave fields, which were then detected using phase-sensitive optical coherence tomography. A 3D-printed acoustic lens array was employed to manipulate a collimated ARF beam generated by an ultrasound transducer, producing multiple focused ARF beams on mouse eye globes . RevOCE measurements were conducted using an excitation pulse train consisting of 10 cycles at 3 kHz, followed by data processing to produce a volumetric map of the shear wave speed.
Results: The results show that the system can successfully generate reverberant shear wave fields in the eye globe, allowing for simultaneous estimation of shear wave speeds in various ocular components, including cornea, iris, lens, sclera, and retina. A comparative analysis revealed notable differences in wave speeds between different parts of the eye, for example, between the apical region of the cornea and the pupillary zone of the iris (). Moreover, the study also revealed regional variations in the biomechanical properties of ocular components as evidenced by greater wave speeds near the apex of the cornea compared to its periphery.
Conclusions: The study demonstrated the effectiveness of RevOCE based on a non-invasive multifocal ARF for assessing the biomechanical properties of the whole eyeball. The findings indicate the potential to provide a comprehensive understanding of the mechanical behavior of the whole eye, which could lead to improved diagnosis and treatment of ocular diseases.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10494982 | PMC |
http://dx.doi.org/10.1117/1.JBO.28.9.095001 | DOI Listing |
Sci Rep
January 2025
College of Civil and Transportation Engineering, Hohai University, No. 1 Xikang Road, Nanjing City, 210098, Jiangsu Province, People's Republic of China.
Aftershocks can cause additional damage or even lead to the collapse of structures already weakened by a mainshock. Scarcity of in-situ recorded aftershock accelerograms heightens the need to develop synthetic aftershock ground motions. These synthesized motions are crucial for assessing the cumulative seismic demand on structures subjected to mainshock-aftershock sequences.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Department of Electrical and Electronic Engineering, The University of Hong Kong, Chow Yei Ching 506, Hong Kong, 999077, HONG KONG.
. The propagation speed of a shear wave, whether externally or internally induced, in biological tissues is directly linked to the tissue's stiffness. The group shear wave speed (SWS) can be estimated using a class of time-of-flight (TOF) methods in the time-domain or phase speed-based methods in the frequency domain.
View Article and Find Full Text PDFFront Oncol
December 2024
Department of Medical Ultrasound, China Resources & Wisco General Hospital, Wuhan University of Science and Technology, Wuhan, China.
Objectives: Shear-wave elastography (SWE) provides valuable stiffness within breast masses, making it a useful supplement to conventional ultrasound imaging. Super-resolution ultrasound (SRUS) imaging enhances microvascular visualization, aiding in the differential diagnosis of breast masses. Current clinical ultrasound diagnosis of breast cancer primarily relies on gray-scale ultrasound.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA. Electronic address:
Objective: Measurement of thenar muscle elasticity by ultrasound shear wave elastography (SWE) may be useful for the diagnosis and evaluation of carpal tunnel syndrome (CTS), but there is a paucity of information on SWE of the thenar muscles in patients with CTS. The purpose of this study was to investigate the elasticity of the thenar muscles in patients with CTS.
Methods: Twenty-two adult patients with a referral diagnosis of CTS (27 hands) and 20 healthy volunteers as a control (20 dominant hands) participated in this study.
Sci Rep
January 2025
Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, No. 34 North Zhongshan Road, Quanzhou, 362000, Fujian Province, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!