Introduction/purpose: Ultrasound-guided popliteal fossa sciatic nerve (PFSN) blocks are performed with patients in the supine, lateral or prone position. No known studies compare the quality of images obtained from each approach. This study examines the quality of supine and prone PFSN ultrasound images.

Methods: Thirty-eight adult volunteers were sorted into two groups. Five regional anaesthesiologists performed ultrasound examinations of the PFSN on volunteers in supine and prone positions. Popliteal fossa sciatic nerve image quality was analysed with grayscale techniques and peer evaluation. Popliteal fossa sciatic nerve depth, distance from the popliteal crease and time until optimal imaging were recorded.

Results: The grayscale ratio of the PFSN vs. the background was 1.83 (supine) and 1.75 (prone) (P = 0.034). Similarly, the grayscale ratio of the PFSN vs. the immediately adjacent area was 1.65 (supine) and 1.55 (prone) (P = 0.004). Mean depth of the PFSN was 1.6 cm (supine) and 1.7 cm (prone) (P = 0.009). Average distance from the popliteal crease to the PFSN was 5.9 cm (supine) and 6.6 cm (prone) (P = 0.02). Mean time to acquire optimal imaging was 36 s (supine) and 47 s (prone) (P = 0.002). Observers preferred supine positioning 53.8%, prone positioning 22.5% and no preference 23.7% of the time. Observers with strong preferences preferred supine imaging in 70.9% of cases.

Conclusions: Supine ultrasound examination offered quicker identification of the PFSN, in a more superficial location, closer to the popliteal crease and with enhanced contrast to surrounding tissue, correlating with observer preferences for supine positioning. These results may influence ultrasound-guided PFSN block success rates, especially in difficult-to-image patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10493341PMC
http://dx.doi.org/10.1002/ajum.12342DOI Listing

Publication Analysis

Top Keywords

sciatic nerve
16
popliteal fossa
16
fossa sciatic
12
supine
12
popliteal crease
12
pfsn
9
prone
9
ultrasound examination
8
supine prone
8
distance popliteal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!